The aim of this study is to evaluate the effect of treatment with the Molecular Adsorbent Recirculating System (MARS) on liver failure based on HBV. In 25 patients (median age, 36.3 years, range, 22-67 years, bilirubin level > 255 micro mol/l) admitted with liver failure based on HBV, the 6-8h MARS intermittent treatments were performed without any adverse events, A significant decrease in bilirubin, ammonia and urea levels were observed (P < 0.05). All patients achieved a remarkable neurologic recovery, particularly 2 HE-III and 3 HE-IV patients regained normal consciousness, respectively. The survival rate for the patients whose treatments kept to the MARS art strategy was 76.9% (10/13), while the others only had the survival rate of 16.7% (2/12) due to their giving up sequential MARS treatments after the first time. The rebounding rate of the bilirubin level in the patients after a single MARS treatment was significantly lower than that of patients, who underwent a single plasma-exchange treatment (P < 0.01). It is concluded that MARS method can contribute to the optimistic treatment of liver failure patients based on HBV which being the major epidemic liver disease in China.
During invasive mechanical ventilation due to the dryness of medical gases is necessary to provide an adequate level of conditioning. The hot water humidifiers (HWH) heat the water, thus allowing the water vapor to heat and humidify the medical gases. In the common HWH there is a contact between the medical gases and the sterile water, thus increasing the risk of patient's colonization and infection. Recently to avoid the condensation in the inspiratory limb of the ventilator circuit, new heated ventilator circuits have been developed. In this in vitro study we evaluated the efficiency (absolute/relative humidity) of three HWH: (1) a common HWH without a heated ventilator circuit (MR 730, Fisher&Paykel, New Zeland), (2) the same HWH with a heated ventilator circuit (Mallinckrodt Dar, Italy) and (3) a new HWH (DAR HC 2000, Mallinkckrodt Dar, Italy) with a heated ventilator circuit in which the water vapor reaches the medical gases through a gorotex membrane, avoiding any direct contact between the water and gases. At a temperature of 35°C and 37°C the HWH and heated tube were evaluated.The absolute humidity (AH) and relative humidity (RH) were measured by a psychometric method. The minute ventilation, tidal volume respiratory rate and oxygen fraction were: 5.8 ± 0.1 l/min, 740 ± 258 ml, 7.5 ± 2.6 bpm and 100%, respectively. Ventilator settings were maintained constant for all the study period. The measurements were taken after 60 min of continuous use.At 35°C the output of the MR 730 with a heated tube was insufficient to provide adequate levels of conditioning, while at 37°C all the three devices were satisfactory. Airway techniques for percutaneous tracheostomy include the LMA, the Combitube, the Microlaryngeal tube and the Perforated Airway Exchanger. Routine bronchoscopy is deemed unnecessary by many, including intensivists in Cardiff. Our audit database stores patient characteristics, techniques and complications, in 700 tracheostomies.A bougie was used during 46. This technique does not use bronchoscopic control. A bougie is passed through the tracheal tube (TT) into the trachea. The TT is withdrawn until the cuff is above the vocal cords. With the cuff fully inflated, the TT is advanced (using the bougie as a guide) until the cuff impacts on the vocal cords. A gas- Critical Care March 2004 Vol 8 Suppl 1 24th International Symposium on Intensive Care and Emergency Medicineseal is maintained by gentle pressure on the TT keeping the cuff pressing on the vocal cords. During percutaneous tracheostomy the bougie remains in the trachea. When ventilation through the tracheostomy tube (cuff inflated) is confirmed, the TT and bougie are withdrawn. Throughout the procedure, if ventilation difficulties occur, the TT can be easily re-inserted using the bougie as a guide.Results Three different bougies were used: types (number used) were Eschmann (29), size 10 Portex disposable (four) and size 12 Portex disposable (13). Three patients were trauma cases: a neutral cervical position was maintained. In 33 cases the Blue ...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.