A hollow cathode discharge (HCD) is described that produces a highly ionized steady-state plasma (ne≈1013−1014/cm3) at a temperature 1–10 eV, in a volume as large as 104 cm3, with background neutral gas density ≈1013/cm3. The HCD is generated by the prescription: gas flow (H2, He, A, or N2) 0.05–2 cc STP/sec through a refractory metal hollow cathode tube into a vacuum; any anode; 20–200 V dc applied. An axial induction 100–1000 G is used to collimate the discharge and to aid in starting by rf excitation. The HCD runs from the cathode interior, deep enough that p0d≈1 cm×mm Hg. Current range is 2.0–300 A. Various electrode configurations and a wide range of operating parameters have been studied. The external plasma density and temperature were measured by Langmuir probes. A discussion is given of the confinement mechanism and of the energy balance, both in the external plasma and in the region of the cathode itself.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.