Natural ventilation (NV) is a strategy of bioclimatic design to promote hygrothermal comfort and indoor air quality (IAQ). Nowadays, COVID-19 pandemic highlights the review of ventilation standards. In Mexico, the IAQ standard states a minimum of 6 ACH for educational buildings. ACH considers NV as an ideal piston flow and does not provide information of indoor airflow distribution. In this work, new age of air associated parameters are proposed, considering the indoor airflow distribution: the air renovation per hour (ARH) and the renovation parameter R. An isolated educational building located in a rural region is studied. Four window configurations of cross-ventilation are considered. All configurations have one windward window located at bottom. The configurations axial and upward have one leeward window at bottom and top, respectively. While, configurations corner and upward corner have one lateral side window at bottom and top, respectively. A CFD model of the educational building is validated with experiments. The axial configuration has the best performance according to ACH, nevertheless has the worst performance according to ARH and R. The results show that NV evaluation using ACH can lead to wrong decisions. An improvement of NV standard with the age of air associated parameters is recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.