We have investigated the magnetism of the bare and graphene-covered (111) surface of a Ni single crystal employing three different magnetic imaging techniques and ab initio calculations, covering length scales from the nanometer regime up to several millimeters. With low temperature spinpolarized scanning tunneling microscopy (SP-STM) we find domain walls with widths of 60 -90 nm, which can be moved by small perpendicular magnetic fields. Spin contrast is also achieved on the graphene-covered surface, which means that the electron density in the vacuum above graphene is substantially spin-polarized. In accordance with our ab initio calculations we find an enhanced atomic corrugation with respect to the bare surface, due to the presence of the carbon pz orbitals and as a result of the quenching of Ni surface states. The latter also leads to an inversion of spinpolarization with respect to the pristine surface. Room temperature Kerr microscopy shows a stripe like domain pattern with stripe widths of 3 -6 µm. Applying in-plane-fields, domain walls start to move at about 13 mT and a single domain state is achieved at 140 mT. Via scanning electron microscopy with polarization analysis (SEMPA) a second type of modulation within the stripes is found and identified as 330 nm wide V-lines. Qualitatively, the observed surface domain pattern originates from bulk domains and their quasi-domain branching is driven by stray field reduction.
A newly designed scanning electron microscope with polarization analysis (SEMPA or spin-SEM) for the acquisition of magnetic images is presented. Core component is the spin detector, based on the scattering of low-energy electrons at a W(100) surface in ultrahigh vacuum. The instrument has been optimized with respect to ease of handling and efficiency. The operation and performance of a general low-energy electron diffraction (LEED) detector for SEMPA have been modeled in order to find the optimum operating parameters and to predict the obtainable image asymmetry. Based on the energy dependence of the secondary electron polarization and intensity, the detector output is simulated. For our instrument with optimized performance we demonstrate experimentally 8.6% polarization asymmetry in the domain structure of an iron whisker. This corresponds to 17.2% image contrast, in excellent agreement with the predicted simulated value. A contrast to noise ratio of 27 is achieved at 5 ms acquisition time per pixel.
We have studied the magnetic domain structure in Permalloy rectangles that reveal flux-closure domain configurations. Arrays with varying spacing between the rectangles are investigated by scanning electron microscopy with polarization analysis as well as by micromagnetic simulation. In contrast to general expectation, rectangles in the flux-closure Landau state show significant coupling and form a magnetic pattern of common chirality. The coupling is due to the stray field that originates from small changes of the magnetization alignment, which is sensitive to the exact shape and the separation of the rectangles.
A magnetic domain texture has been deterministically engineered in a topographically flat exchange-biased (EB) thin film system. The texture consists of long-range periodically arranged unit cells of four individual domains, characterized by individual anisotropies, individual geometry, and with non-collinear remanent magnetizations. The texture has been engineered by a sequence of light-ion bombardment induced magnetic patterning of the EB layer system. The magnetic texture's in-plane spatial magnetization distribution and the corresponding domain walls have been characterized by scanning electron microscopy with polarization analysis (SEMPA). The influence of magnetic stray fields emerging from neighboring domain walls and the influence of the different anisotropies of the adjacent domains on the Néel type domain wall core's magnetization rotation sense and widths were investigated. It is shown that the usual energy degeneracy of clockwise and counterclockwise rotating magnetization through the walls is revoked, suppressing Bloch lines along the domain wall. Estimates of the domain wall widths for different domain configurations based on material parameters determined by vibrating sample magnetometry were quantitatively compared to the SEMPA data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.