On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ∼ 1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40 − 8 + 8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 M ⊙ . An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ∼ 40 Mpc ) less than 11 hours after the merger by the One-Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ∼10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ∼ 9 and ∼ 16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC 4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta.
In this paper, we have selected a sample of 64 teraelectronvolt blazars, with redshift, from those classified in the fourth Fermi Large Area Telescope source catalog a) . We have obtained the values of the relevant physical parameters by performing a log-parabolic fitting of the average-state multiwavelength spectral energy distributions. We estimate the range of the radiation zone parameters, such as the Doppler factor (D), the magnetic field strength (B), the radiative zone radius (R) and the peak Lorentz factor (γ p ) of nonthermal electrons. Here, we show that (1) there is a strong linear positive correlation between the intrinsic synchrotron peak frequency and the intrinsic inverse Compton scattering (ICs) peak frequency among different types of blazars; (2) if radio bands are excluded, the spectral index of each band is negatively correlated with the intrinsic peak frequency; (3) there is a strong linear negative correlation between the curvature at the peak and the intrinsic peak frequency of the synchrotron bump, and a weak positive correlation between the curvature at the peak and the intrinsic peak frequency of the ICs bump; (4) there is a strong linear positive correlation between the intrinsic ICs peak luminosity and intrinsic γ-ray luminosity and between the intrinsic ICs peak frequency and peak Lorentz factor;(5) there is a strong negative linear correlation between log B and log γ p ; and (6) there is no correlation between log R and log γ p .
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space Station. To realize wide-band detection from 20 keV to 1 MeV, we use Ce:GAGG scintillators, each coupled to an APD, with low-noise front-end electronics capable of achieving a minimum energy detection threshold of 20 keV. The developed ASIC has the ability to read out 32-channel APD signals using 0.35 µm CMOS technology, and an analog amplifier at the input stage is designed to suppress the capacitive noise primarily arising from the large detector capacitance of the APDs. The ASIC achieves a performance of 2099 e − + 1.5 e − /pF at root mean square (RMS) with a wide 300 fC dynamic range. Coupling a reverse-type APD with a Ce:GAGG scintillator, we obtain an energy resolution of 6.7% (FWHM) at 662 keV and a minimum detectable energy of tolerance for space applications by using a 90 MeV proton beam, confirming that the ASIC is free of single-event effects and can operate properly without serious degradation in analog and digital processing.
The long gamma-ray burst GRB 161017A was detected by Fermi and Swift, and its afterglow was observed by the MITSuME 50-cm optical telescope promptly about 50 s after the burst. Early optical observations revealed that the optical lightcurve exhibits a plateau and rebrightening in the early afterglow phase about 500 and 5000 s after the trigger, respectively. By investigating the behavior of the spectral and temporal flux variation, it was found that the plateau and re-brightening cannot be explained in the context of the simple standard afterglow model. These observational features can be explained with two independent refreshed shocks, which indicate the long-acting central engine. We evaluated the physical parameters of the subsequent shells, and we then determined the kinetic energy ratio of the two colliding shells to the leading shell to be roughly 1 and 8, respectively. In addition, two prominent X-ray flares about 200 s after the trigger may be signatures of delayed ejections of the energetic jets responsible for the refreshed shocks. Such late activity of the central engine and X-ray flares play a crucial role in understanding the mechanisms for jet formation and photon emission.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.