Study of the relationship between ventilation parameters: monitored expiratory time constant -τedyn and breathing -trigger frequency (ftrig) and time of breathing cycle (Tcy) are main goals of this article. Parameters were analyzed during last 4±2 h before weaning from ventilation in 66 patients ventilated in pressure support mode (PSV). We have found out, that there exist mathematical relationships, observed during adequate gas exchange, yet not described. Monitored parameters are represented by τedyn, ftrig and Tcy. The analysis showed close negative correlation between Tcy and ftrig (R 2 =0.903). This implies that each increasing of τedyn causes decreasing of ftrig and vice versa. The calculation of regression equation between τedyn and Tcy outlined that Tcy = 5.2625 * τedyn + 0.1242 (R 2 =0.85). Regulation of respiratory cycles by the respiratory center in the brain is probably based on evaluation of τedyn as the τedyn probably represents a regulatory element and Tcy regulated element. It can be assumed, that respiratory center can optimize the work of breathing in order to minimize energy in system patient + ventilator. The unique relationship, described above could be useful in clinical practice for development of new ventilation modes. Key words Time constant • Weaning from ventilator • Time of breathing cycle • Breathing cycle
The main goal of our prospective randomized study was comparing compare the effectiveness of ventilation control method „Automatic proportional minute ventilation (APMV) “versus manually set pressure control ventilation modes in relationship to lung mechanics and gas exchange. 80 patients undergoing coronary artery bypass grafting (CABG) were randomized into 2 groups. 40 patients in the first group No. 1 (APMV group) were ventilated with pressure control (PCV) or pressure support ventilation (PSV) mode with APMV control. The other 40 patients (control group No.2) were ventilated with synchronized intermittent mandatory ventilation (SIMV-p) or pressure control modes (PCV) without APMV. Ventilation control with APMV was able to maintain minute ventilation more precisely in comparison with manual control (p<0.01), similarly deviations of ETCO2 were significantly lower (p<0.01). The number of manual corrections of ventilation settings was significantly lower when APMV was used (p<0.01). The differences in lung mechanics and hemodynamics were not statistically significant. Ventilation using APMV is more precise in maintaining minute ventilation and gas exchange compared with manual settings. It required less staff intervention, while respiratory system mechanics and hemodynamics are comparable. APMV showed as effective and safe method applicable on top of all pressure control ventilation modes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.