A numerical study has been performed to investigate the effect of tip geometry on the tip leakage flow and heat transfer characteristics in unshrouded axial flow turbines. Base line flat tip geometry and squealer type geometries, namely, double squealer or cavity and suction-side squealer, were considered. The performances of the squealer geometries, in terms of the leakage mass flow and heat transfer to the tip, were compared with the flat tip at two different tip clearance gaps. The computations were performed using a single blade with periodic boundary conditions imposed along the boundaries in the pitchwise direction. Turbulence was modeled using three different models, namely, standard k-ε, low Re k-ω, and shear stress transport (SST) k-ω, in order to assess the capability of the models in correctly predicting the blade heat transfer. The heat transfer and static pressure distributions obtained using the SST k-ω model were found to be in close agreement with the experimental data. It was observed that compared to the other two geometries considered, the cavity tip is advantageous both from the aerodynamic and from the heat transfer perspectives by providing a decrease in the amount of leakage, and hence losses, and average heat transfer to the tip. In general, for a given geometry, the leakage mass flow and the heat transfer to the tip increased with increase in tip clearance gap. Part II of this paper examines the effect of relative casing motion on the flow and heat transfer characteristics of tip leakage flow. In Part III of this paper the effect of coolant injection on the flow and heat transfer characteristics of tip leakage flow is presented.
Local measurements of the heat transfer coefficient and pressure coefficient were conducted on the tip and near tip region of a generic turbine blade in a five-blade linear cascade. Two tip clearance gaps were used: 1.6% and 2.8% chord. Data was obtained at a Reynolds number of 2.3×105 based on exit velocity and chord. Three different tip geometries were investigated: A flat (plain) tip, a suction-side squealer, and a cavity squealer. The experiments reveal that the flow through the plain gap is dominated by flow separation at the pressure-side edge and that the highest levels of heat transfer are located where the flow reattaches on the tip surface. High heat transfer is also measured at locations where the tip-leakage vortex has impinged onto the suction surface of the aerofoil. The experiments are supported by flow visualization computed using the CFX CFD code which has provided insight into the fluid dynamics within the gap. The suction-side and cavity squealers are shown to reduce the heat transfer in the gap but high levels of heat transfer are associated with locations of impingement, identified using the flow visualization and aerodynamic data. Film cooling is introduced on the plain tip at locations near the pressure-side edge within the separated region and a net heat flux reduction analysis is used to quantify the performance of the successful cooling design.
A numerical study has been performed to investigate the effect of casing motion on the tip leakage flow and heat transfer characteristics in unshrouded axial flow turbines. The relative motion between the blade tip and the casing was simulated by moving the casing in a direction from the suction side to the pressure side of the stationary blade. Base line flat tip geometry and squealer type geometries, namely, double squealer or cavity and suction side squealer, were considered at a clearance gap of 1.6%C. The computations were performed using a single blade with periodic boundary conditions imposed along the boundaries in the pitchwise direction. Turbulence was modeled using the shear stress transport k-ω model. The flow conditions correspond to an exit Reynolds number of 2.3×105. The results were compared to those obtained without the relative casing motion reported in Part I of this paper. In general, the effect of relative casing motion was to decrease the tip leakage mass flow and the average heat transfer to the tip due to the decrease in leakage flow velocity caused by a drop in driving pressure difference. Compared to the computations with stationary casing, in the case of all the three geometries considered, the average heat transfer to the suction surface of the blade was found to be larger in the case of the computations with relative casing motion. At a larger clearance gap of 2.8%C, in case of a flat tip, while the tip leakage mass flow decreased due to relative casing motion, only a smaller change in the average heat transfer to the tip and the suction surface of the blade was noticed.
Contours of heat transfer coefficient and effectiveness have been measured on the tip of a generic cooled turbine blade, using the transient liquid crystal technique. The experiments were conducted at an exit Reynolds number of 2.3×105 in a five-blade linear cascade with tip clearances of 1.6% and 2.8% chord and featuring engine-representative cooling geometries. These experiments were supported by oil-flow visualization and pressure measurements on the tip and casing and by flow visualization calculated using CFX, all of which provided insight into the fluid dynamics within the gap. The data were compared with measurements taken from the uncooled tip gap, where the fluid dynamics is dominated by flow separation at the pressure-side edge. Here, the highest levels of heat transfer are located where the flow reattaches on the tip surface downstream of the separation bubble. A quantitative assessment using the net heat flux reduction (NHFR) revealed a significant benefit of ejecting coolant inside this separation bubble. Engine-representative blowing rates of approximately 0.6–0.8 resulted in good film-cooling coverage and a reduction in heat flux to the tip when compared to both the flat tip profile and the squealer and cavity tip geometries discussed in Part 1 of this paper. Of the two novel coolant-hole configurations studied, injecting the coolant inside the separation bubble resulted in an improved NHFR when compared to injecting coolant at the location of reattachment.
A numerical study has been performed to investigate the effect of casing motion on the tip leakage flow and heat transfer characteristics in unshrouded axial flow turbines. The relative motion between the blade tip and the casing was simulated by moving the casing in a direction from the suction side to the pressure side of the stationary blade. Baseline flat tip geometry and squealer type geometries namely double squealer or cavity and suction side squealer were considered at a clearance gap of 1.6%C. The computations were performed using a single blade with periodic boundary conditions imposed along the boundaries in the pitchwise direction. Turbulence was modelled using the SST k-ω model. The flow conditions correspond to an exit Reynolds number of 2.3×105. The results were compared with those obtained without the relative casing motion reported in part I of this paper. In general, the effect of relative casing motion was to decrease the tip leakage mass flow and the average heat transfer to the tip due to the decrease in leakage flow velocity caused by a drop in driving pressure difference. Compared to the computations with stationary casing, in the case of all the three geometries considered, the average heat transfer to the suction surface of the blade was found to be larger in the case of the computations with relative casing motion. At a larger clearance gap of 2.8%C, in case of flat tip, while the tip leakage mass flow decreased due to relative casing motion only a smaller change in the average heat transfer to the tip and the suction surface of the blade was noticed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.