Abstract-Six contracts have been placed with industrial companies for the production of 1200 tons of the superconducting (SC) cables needed for the main dipoles and quadrupoles of the Large Hadron Collider (LHC). In addition, two contracts have been placed for the supply of 470 tons of NbTi and 26 tons of Nb sheets. The main characteristic of the specification is that it is functional. This means that the physical, mechanical and electrical properties of strands and cables are specified without defining the manufacturing processes. Facilities for the high precision measurements of the wire and cable properties have been implemented at CERN, such as strand and cable critical current, copper to superconductor ratio, interstrand resistance, magnetization, RRR at 4.2 K and 1.9 K. The production has started showing that the highly demanding specifications can be fulfilled. This paper reviews the organization of the contracts, the test facilities installed at CERN, the various types of measurements and the results of the main physical properties obtained on the first batches. The status of the deliveries is presented.
Abstract-The knowledge of the critical current density in a wide temperature and applied magnetic field range is a crucial issue for the design of a superconducting magnet, especially for determining both current and temperature margins. The critical current density of LHC-type Nb Ti strands of 0.82 and 0.48 mm diameter was measured by means of critical current and magnetization measurements at both 4.2 K and 1.9 K and for a broad magnetic field range (up to 11 T). For the magnetic field range common to both measurement methods, critical current density values as extracted from transport current and from magnetization data are compared and found fairly consistent. Our experimental data are compared to other sets from literature and to scaling laws as well.
When using superconducting magnets in particle accelerators like the LHC, persistent currents in the superconductor often determine the field quality at injection, where the magnetic field is low. This paper describes magnetization measurements made on LHC cable strands at the Technical University of Vienna and the Institute of Physics of the Polish Academy of Sciences in collaboration with CERN. Measurements were performed at T=2K and T=4.2K on more than 50 strands of 7 different manufacturers with NbTi filament diameter between 5 and 7 micrometer. Two different measurement set-ups were used: vibrating sample magnetometer, with a sample length of about 8mm, and an integrating coil magnetometer, with sample length of about 1m. The two methods were compared by measuring the same sample. Low field evidence of proximity effect is discussed. Statistics like ratio of the width of the magnetization loop at 4.2K and 2K, and the initial slope dM/dB after cooldown are presented. Decrease of the magnetization with time, of the order of 2% per hour, was observed in some samples. Abstract When using superconducting magnets in particle accelerators like the LHC, persistent currents in the superconductor often determine the field quality at injection, where the magnetic field is low. This paper describes magnetization measurements made on LHC cable strands at the Technical University of Vienna and the Institute of Physics of the Polish Academy of Sciences in collaboration with CERN. Measurements were performed at T=2K and T=4.2K on more than 50 strands of 7 different manufacturers with NbTi filament diameter between 5 and 7 micrometer. Two different measurement set-ups were used: vibrating sample magnetometer, with a sample length of about 8mm, and an integrating coil magnetometer, with sample length of about 1m. The two methods were compared by measuring the same sample. Low field evidence of proximity effect is discussed. Statistics like ratio of the width of the magnetization loop at 4.2K and 2K, and the initial slope dM/dB after cooldown are presented. Decrease of the magnetization with time, of the order of 2% per hour, was observed in some samples.
A fully digital system, improving measurements flexibility, integrator drift, and current control of superconducting transformers for cable test, is proposed. The system is based on a high-performance integration of Rogowski coil signal and a flexible direct control of the current into the secondary windings. This allows state-of-the-art performance to be overcome by means of out-of-the-shelf components: on a full-scale of 32 kA, current measurement resolution of
Abstract-One of the main issues for the operation of the LHC accelerator at CERN is the field errors generated by persistent and coupling currents in the main dipoles at injection conditions, i.e., 0.54 T dipole field. For this reason we are conducting systematic magnetic field measurements to quantify the above effects and compare them to the expected values from measurement on strands and cables. We discuss the results in terms of DC effects from persistent current magnetization, AC effects with short time constant from strand and cable coupling currents, and long-term decay during constant current excitation. Average and spread of the measured field errors over the population of magnets tested are as expected or smaller. Field decay at injection, and subsequent snap-back, show for the moment the largest variation from magnet to magnet, with weak correlation to parameters that can be controlled during production. For this reason these effects are likely to result in the largest spread of field errors over the whole dipole production.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.