Objective: To determine whether CT-perfusion (CT-p) can be used to evaluate the effects of chemotherapy and anti-angiogenic treatment in patients with non-small-cell lung carcinoma (NSCLC) and whether CT-p and standard therapeutic response assessment (RECIST) data obtained before and after therapy correlate. Methods: 55 patients with unresectable NSCLC underwent CT-p before the beginning of therapy and 50 of them repeated CT-p 90 days after it. Therapeutic protocol included platinum-based doublets plus bevacizumab for non-squamous carcinoma and platinum-based doublets for squamous carcinoma. RECIST measurements and calculations of blood flow (BF), blood volume (BV), time to peak (TTP) and permeability surface (PS) were performed, and baseline and post-treatment measurements were tested for statistically significant differences. Baseline and follow-up perfusion parameters were also compared based on histopathological subclassification (2004 World Health Organization Classification of Tumours) and therapy response assessed by RECIST. Results: Tumour histology was consistent with large cell carcinoma in 14/50 (28%) cases, adenocarcinoma in 22/50 (44%) cases and squamous cell carcinoma in the remaining 14/50 (28%) cases. BF and PS differences for all tumours between baseline and post-therapy measurements were significant (p50.001); no significant changes were found for BV (p50.3) and TTP (p50.1). The highest increase of BV was demonstrated in adenocarcinoma (5.2634.1%), whereas the highest increase of TTP was shown in large cell carcinoma (6.9622.4%), and the highest decrease of PS was shown in squamous cell carcinoma (221.5618.5%). A significant difference between the three histological subtypes was demonstrated only for BV (p,0.007). On the basis of RECIST criteria, 8 (16%) patients were classified as partial response (PR), 2 (4%) as progressive disease (PD) and the remaining 40 (80%) as stable disease (SD). Among PR, a decrease of both BF (1869.6%) and BV (12.669.2%) were observed; TTP increased in 3 (37.5%) cases, and PS decreased in 6 (75%) cases. SD patients showed an increase of BF, BV, TTP and PS in 6
Patients with middle lobe syndrome show a wide range of parenchymal and bronchial abnormalities at diagnosis. Compared with MR imaging, chest X-ray seems to underestimate these changes. Chest MR imaging might represent a feasible and radiation-free option for an overall assessment of the lung in the follow-up of patients with middle lobe syndrome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.