Integrated presentation of total emissions on catchment scale is prerequisite for many tasks in integrated management of point and diffuse sources of pollution. This paper will focus on emissions of nutrients from municipal point sources. Based on calculations of discharges of N, P from households into wastewater and on the detailed evaluation of data from 76 municipal wastewater treatments plants, this paper presents ranges of specific loads of inhabitants and population equivalents in the raw wastewater. In addition data of these treatment plants have been evaluated in respect of the treatment efficiency for nitrogen and phosphorus (average reduction rates) dependent on the design characteristic (with or without nitrification, denitrification or enhanced phosphorus removal). The results of the investigation show that the specific N and P loads from households in Austria lie within the range 1.6-2.0 g P/(inhabitant.d) and 11- 13 g N/(inhabitant.d). The specific contribution of industries to municipal wastewater varies between 0.3 and 2.0 gP/(pe.d) and 0 and 13 g N/(pe.d) with average values of 1.3 g P/(pe.d) and 6.5 g N/(population equivalent (pe)/d). As average values for municipal wastewater (contributions from household and industry) this leads to specific influent loads of 1.5 g P/(pe.d) and 8.8 g N/(pe.d). Average treatment efficiencies of treatment plants are for instance 50% nitrogen removal in treatment plants with nitrification and 80% in treatment plants with nitrification/denitrification. For phosphorus a removal of about 85% can be expected where the treatment plant was designed for enhanced phosphorus removal. Finally a method for load estimations based on standard values as mentioned above was tested for the estimation of emission from municipal point sources of selected regions.
This paper investigates the costs of wastewater treatment (including sludge management) within the Danube catchment countries A, CZ, SK, HU, SL, RO, BG and UA. TK is considered as well. Additionally, the paper compares the total costs of wastewater management (including sewage) with the incomes in the different countries. The annual costs of wastewater treatment in Austria are about 30 euro/p.e. y for large plants with nitrogen and phosphorus removal. In low income countries of the Danube and Black Sea catchment areas they are at a maximum 30% lower than in Austria. However, the incomes in countries like Bulgaria, Romania or Ukraine are 85% to 90% lower. The total annual costs for wastewater management (sewer development plus treatment) amount at least to 90 euro/p.e. y. Considering the level of income in those countries, financing of wastewater management completely by charges of the population equivalents connected is not feasible. Therefore other approaches for financing wastewater treatment are required.
This work presents operating costs and energy consumption of Austrian municipal wastewater treatment plants (WWTPs) (≥10,000 PE-design capacity) that have been classified into different size groups. Different processes as well as cost elements are investigated and processes with high relevance regarding operating costs and energy consumption are identified. Furthermore, the work shows the cost-relevance of six investigated cost elements. The analysis demonstrates the size-dependency of operating costs and energy consumption. For the examination of the energy consumption the investigated WWTPs were further classified into WWTPs with aerobic sludge stabilisation and WWTPs with mesophilic sludge digestion. The work proves that energy consumption depends mainly on the type of sludge stabilisation. The results of the investigation can help to determine reduction potential in operating costs and energy consumption of WWTPs and form a basis for more detailed analysis which helps to identify cost and energy saving potential.
During a six-year period the Austrian Benchmarking System was developed. The main objectives of this benchmarking system are the development of process indicators, identification of best performance and determination of cost reduction potentials. Since 2004 this system is operated via an internet platform and automated to a large extent. Every year twenty to thirty treatment plants use the web-based access to this benchmarking platform. The benchmarking procedure comprises data acquisition, data evaluation including reporting and organised exchange of experience for the treatment plant managers. The process benchmarking method links the real costs with four defined main processes and two support processes. For wastewater treatment plants with a design capacity >100,000 PE these processes are further split up into sub-processes. For each (sub-) process the operating costs are attributed to six cost elements. The specific total yearly costs and the yearly operating costs of all (sub-)processes are related to the measured mean yearly pollution load of the plant expressed in population equivalents (PE(110): 110 gCOD/d corresponding to 60 g BOD(5)/d)). The specific capital costs are related to the design capacity (PE). The paper shows the benchmarking results of 6 Austrian plants with a design capacity >100,000 PE representing approximately 30% of the Austrian municipal wastewater treatment plant capacity.
Dynamic adaptation of the aerated volume to changing load conditions is essential to maximise the nitrogen removal performance and to minimise energy consumption. A control strategy is presented which provides optimum aerobic volume control (OAV-control concept) based on continuous in-line oxygen uptake monitoring. For ammonium concentrations below 1 mg/l the oxygen uptake rate shows a strong and almost linear dependency on the ammonium concentration. Therefore, the oxygen uptake rate is an ideal indicator for the nitrification performance in activated sludge systems. The OAV-control concept provides dynamic variation of the minimum aerobic volume required for complete nitrification and therefore maximises the denitrification performance. In-line oxygen uptake monitoring is carried out by controlling the oxygen concentration in a continuous aerated zone of the aeration tank and measuring the total air flow to the aeration tank. The total air flow to the aeration tank is directly proportional to the current oxygen uptake rate and can therefore be used as an indicator for the required aerobic volume. The instrumentation requirements for installation of the OAV-control are relatively low, oxygen sensors in the aeration tank and an on-line air flow measurement are needed. This enables individual control of aeration tanks operated in parallel at low investment costs. The OAV-control concept is installed at the WWTP Linz-Asten (1 Mio PE) and shows very good results. Full scale results are presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.