The current Boron Neutron Capture Therapy (BNCT) experiments performed at the University of Pavia, Italy, are focusing on the in vivo irradiations of small animals (rats and mice) in order to evaluate the effectiveness of BNCT in the treatment of diffused lung tumors. After the irradiation, the animals are manipulated, which requires an evaluation of the residual radioactivity induced by neutron activation and the relative radiological risk assessment to guarantee the radiation protection of the workers. The induced activity in the irradiated animals was measured by high-resolution open geometry gamma spectroscopy and compared with values obtained by Monte Carlo simulation. After an irradiation time of 15 min in a position where the in-air thermal flux is about 1.2 × 10(10) cm(-2) s(-1), the specific activity induced in the body of the animal is mainly due to 24Na, 38Cl, 42K, 56Mn, 27Mg and 49Ca; it is approximately 540 Bq g(-1) in the rat and around 2,050 Bq g(-1) in the mouse. During the irradiation, the animal body (except the lung region) is housed in a 95% enriched 6Li shield; the primary radioisotopes produced inside the shield by the neutron irradiation are 3H by the 6Li capture reaction and 18F by the reaction sequence 6Li(n,α)3H → 16O(t,n)18F. The specific activities of these products are 3.3 kBq g(-1) and 880 Bq g(-1), respectively.
The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with (10)B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma radiation in a mixed field. Irradiations were carried out inside the thermal column of a TRIGA MARK II water-pool-type research nuclear reactor, also used for Boron Neutron Capture therapy (BNCT) applications, with thermal neutron fluence from 10(9) to 10(14) nth cm(-2). The ESR dosemeters using the alanine-boron compound indicated ESR signals about 30-fold stronger than those using only alanine. Moreover, a negligible correction for the gamma contribution, measured with TL detectors, almost insensitive to thermal neutrons, was necessary. Therefore, a simultaneous analysis of our TL and ESR detectors allows discrimination between thermal neutron and gamma doses, as required in BNCT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.