Abstract-Cranial defects which are caused by bone tumors or traffic accidents are treated by cranioplasty techniques. Cranioplasty implants are required to protect the underlying brain, correct major aesthetic deformities, or both. With the rapid development of computer graphics, medical image processing (MIP) and manufacturing technologies in recent decades, nowadays, personalised cranioplasty implants can be designed and made to improve the quality of cranial defect treatments. However, software tools for MIP and 3D modelling of implants are expensive; and they normally require high technical skills. Especially, the process of design and development of personalised cranioplasty implants normally requires a multidisciplinary team, including experts in MIP, 3D design and modelling, and Biomedical Engineering; this leads to challenges and difficulties for technology transfers and implementations in hospitals. This research is aimed at developing, in particular, cost-effective solutions and tools for design and modeling of personalised cranioplasty implants, and to simplify the design and modelling of implants, as well as to reduce the design and modeling time. In this way, surgeons and engineers can conveniently and easily design personalised cranioplasty implants, without the need of using complex MIP and CAD tools; and as a result the cost of implants will be minimised.
Friction measurements were made on two testers: the Jenike shear tester and a linear abrasive wear tester (LAWT). Wall friction values were obtained for a range of steels and surface finishes, typical of the plates used for the manufacture of hoppers and silos in bulk solids handling applications. The abrasive used was crushed soda-lime glass. It was found that friction values on the Jenike were similar to the initial 'start up' values obtained on the LAWT. The latter correlated particularly well with the surface roughness of the sample plates. On the LAWT, friction was found to increase with sliding distance until a steady-state level was attained. It is considered that this increase is due to the gradual accumulation of wear debris, particularly fragmented abrasive particles, on the surface of the wear specimen.
Abstract-Cranial defects which are caused by bone tumors or traffic accidents are treated by cranioplasty techniques. Cranioplasty implants are required to protect the underlying brain, correct major aesthetic deformities, or both. With the rapid development of computer graphics, medical image processing (MIP) and manufacturing technologies in recent decades, nowadays, personalised cranioplasty implants can be designed and made to improve the quality of cranial defect treatments. However, software tools for MIP and 3D modelling of implants are expensive; and they normally require high technical skills. Especially, the process of design and development of personalised cranioplasty implants normally requires a multidisciplinary team, including experts in MIP, 3D design and modelling, and Biomedical Engineering; this leads to challenges and difficulties for technology transfers and implementations in hospitals. This research is aimed at developing, in particular, cost-effective solutions and tools for design and modeling of personalised cranioplasty implants, and to simplify the design and modelling of implants, as well as to reduce the design and modeling time. In this way, surgeons and engineers can conveniently and easily design personalised cranioplasty implants, without the need of using complex MIP and CAD tools; and as a result the cost of implants will be minimised.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.