We investigated the in vitro viscoelastic changes of progressive haemodilution with 4% albumin compared with normal saline (NS) using rotational thromboelastometry (ROTEM®, Pentapharm Co., Munich, Germany). Whole blood samples obtained from 20 healthy volunteers were diluted in vitro with 4% albumin or NS by 10%, 20% and 40%. Fibrinogen concentration and ROTEM® (EXTEM [screening test for the extrinsic haemostasis system], FIBTEM [EXTEM-based assay for the fibrin part of the clot]) variables including coagulation time, clot formation time (CFT), α-angle, maximum clot firmness and lysis index were measured in the undiluted sample and at each degree of haemodilution. There was no significant difference in fibrinogen concentration at equivalent haemodilutions with normal saline and 4% albumin solutions. Forty percent haemodilution with albumin significantly prolonged coagulation time (EXTEM P=0.007, FIBTEM P=0.0001) and significantly decreased lysis index (FIBTEM P=0.009) compared with NS. A significant decrease in maximum clot firmness from undiluted measurements (P=0.05) was observed at lower haemodilutions with albumin (20% with EXTEM, 10% with FIBTEM) compared with NS (40% with EXTEM and FIBTEM). The adverse effects of large degrees of haemodilution with 4% albumin solution are in excess of what can be explained by haemodilution alone. This study suggests that large degrees of haemodilution with albumin impair fibrinogen activity to a greater extent than equivalent degrees of haemodilution with NS.
Over the past decade there has been an exponential increase in the number of robotic-assisted surgical procedures performed in Australia and internationally. Despite this growth, there are no level I or II studies examining the anaesthetic implications of these procedures. Available observational studies provide insight into the significant challenges for the anaesthetist. Most anaesthetic considerations overlap with those of non-robotic surgery. However, issues with limited patient access and extremes of positioning resulting in physiological disturbances and risk of injury are consistently demonstrated concerns specific to robotic-assisted procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.