A radioimmunoassay is described that measures budesonide in plasma after solid-phase extraction (SPE/RIA) of the analyte. The performance of the assay was compared with that of a selective LC/MS method. The limit of quantitation of budesonide determined for the LC/MS and SPE/RIA assay was 50 pg/mL and 120 pg/mL, respectively. Based on quality control samples, a higher variability was observed for the SPE/RIA (CV between 4.5 and 23.0%) than for the LC/MS method (CV between 7.5 and 12.5%). Plasma samples obtained from healthy volunteers after administration of budesonide rectal foam were assayed by both methods. In a subset of samples, these results were compared with those measured by direct RIA to evaluate the selectivity of two assays. About two times higher budesonide levels were measured with the direct RIA (lacking the extraction step), presumably because of cross-reactivity with budesonide metabolites, indicating that the extraction step in SPE/RIA is necessary for selectivity. Both SPE/RIA and LC/MS methods were found to be selective, sensitive and suitable for pharmacokinetic studies. Results obtained from the two methods were compared with a number of statistical methods. Ratios of results obtained for the clinical samples were close to 1 (ratio LC-MS/ SPE/RIA = 0.98 +/- 0.27). Linear regression indicated a slope of 1.17 +/- 0.0378. The concordance correlation (r = 0.91) indicated that the agreement between both methods was fair while the Bland-Altman plot indicated that the agreement was less pronounced at higher concentrations (1-3 ng/mL). In summary, the results confirm that the SPE/RIA is an alternative to HPLC/MS and that among the statistical methods tested the concordance correlation analysis was judged to be the most informative test to assess the comparability of two methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.