A fully validated and rapid RP-HPLC method suitable for the quantification of formoterol fumarate and glycopyrrolate combination is reported. Chromatographic separation was achieved on a Sunsil C18 analytical column (250 mm × 4.6 mm, 5 µ particle size). The analytes were detected and quantified by photodiode array detector set at 289 nm. Calibration curves were constructed in the range of 4.8-14.4 µg/ mL (R 2 = 0.9997) with a limit of quantification of 0.279 µg/mL for formoterol fumarate and 9-27 µg/mL (R 2 = 0.9998) with a limit of quantification 0.239 µg/mL for glycopyrrolate. The method was validated aaccording to ICH guidelines. The developed and validated RP-HPLC method was sensitive, selective, robust, accurate and precise for the simultaneous estimation of formoterol fumarate and glycopyrrolate in quality control laboratories.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.