The STARFlex device seems to offer better results than the CardioSEAL, with significantly lower rates of residual shunts and arm fractures.
After operative correction of congenital heart defects in selected patients who show severe dysfunction of the right ventricle caused by pulmonary regurgitation/stenosis, mechanical valves may represent an alternative to bioprosthetic valves. The selection of the valve type is still a matter of debate. However, according to literature data, complications seem to have occurred only in patients with bileaflet mechanical valves in the pulmonary position, whereas no thromboembolic episodes or valve failure is reported in subjects with tilting disc valves in the right ventricular outflow. Tilting disc valves might perform better in the right ventricular outflow than bileaflet valves.
Isolated right ventricular hypoplasia is a rare congenital anomaly. This condition is usually associated with a communication between the atria in the form of a patent foramen ovale or secondum atrial septal defect. We describe a familial occurrence of this rare disease. A 1-day-old male child and his 34-year-old father were found to have isolated right ventricular hypoplasia with atrial septal defect. An autosomal dominant mode of inheritance is likely for this rare congenital anomaly.
Between February 1988 and September 1993 balloon aortic valvuloplasty was attempted in 33 consecutive patients in the first year of life: 20 patients (61%) were younger than 1 month. Major associated anomalies such as mitral stenosis, coarctation, and hypoplastic left ventricle were found in 11 cases (33%). The balloon dilation of the aortic valve was accomplished through the right carotid cut-down approach in neonates and patients with body weight < 5 kg, through a percutaneous femoral approach in the others; the procedure was completed in all. The peak systolic gradient across the aortic valve measured at catheterization fell from 80 +/- 33 mmHg (range 25-165) before the dilation to 27 +/- 17 mmHg (range 0-65), afterwards (p < 0.0001). The left ventricular ejection fraction increased from 44% +/- 26% to 61% +/- 17%, 24-48 hours after the procedure (p < 0.0001). Aortic insufficiency developed in 17 cases, being moderate in 2, mild in 6, and trivial in 9. Seven patients (21%), all in the first month of life, died within 30 days from the valvuloplasty; major associated anomalies were present in six; the death was due to a procedure related complication in one. No mortality was observed among the patients undergoing valvuloplasty beyond the first month of life. On follow-up (6 months to 6 years) aortic restenosis occurred in 3 cases; 1 was treated by surgical valvotomy, 2 by repeat balloon valvatomy; in another 2 cases, a subvalvular aortic obstruction developed and was relieved by surgical resection. There was no late mortality. Thus, balloon valvuloplasty appears to be an effective palliation for critical aortic stenosis in infancy. Early mortality is mainly related to associated anomalies.
SummaryBalloon dilation of the aortic valve was performed in 20 consecutive neonates with critical aortic stenosis using an approach achieved by cutting down on the right carotid artery. The age of the patients ranged from one to 25 days (mean seven days) and their weight from 2.1 to 4.0 kg (mean 3.16 kg). All patients were evaluated before cardiac catheterization with cross-sectional and Doppler echocardiography so as to keep the catheterization procedure as short as possible. Balloon dilation was accomplished in all patients. The only complication was an apical perforation by the guide wire in two cases. The ensuing pericardial effusion was immediately drained with pericardiocentesis and the subsequent course of the procedure was uneventful. Immediate results showed dramatic improvement in cardiovascular conditions. The transvalvar pressure gradient fell from 80±40 to 27±20 mm Hg (p<0.001). Left ventricular ejection fraction evaluated by echocardiography increased from 30±21% before dilation to 54±18% 24-48 hours after the procedure (p<0.001). In all patients, the procedure was free from vascular complications. Aortic regurgitation was documented after the procedure in 11 patients, being severe in one, moderate in five and trivial in five. Seven patients died, although in only one was the death related directly to the procedure itself. Six patients died because of associated lesions despite an immediate satisfactory result of the balloon valvoplasty. The 13 surviving patients are doing well, and are receiving no medications. During a mean follow-up of 25 months (range 2-54 months), four patients have developed restenosis. One underwent surgical valvotomy at one year of age. The second was successfully redilated through the same approach at two months of age. The other two have a significant gradient, as assessed by Doppler measurements (60 and 70 mm Hg), with normal systolic ventricular function. Two patients have moderate aortic regurgitation. Balloon dilation achieved through cutdown on the right carotid artery is a safe and effective alternative to surgery in neonates with isolated aortic stenosis. The unfavorable results are mainly due to associated anomalies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.