in Wiley InterScience (www.interscience.wiley.com).Stable operation of fluidized-bed heat exchangers during freeze concentration is limited by the rate of ice removal from the cooling surfaces. Operation remains stable as long as the erosion rate caused by the fluidized particles is equal or greater then the ice growth rate. An empirical model has been devised to estimate the erosion rate at different operating conditions. 4 and 5 mm equilateral cylindrical particles made of stainless steel (SS304) were fluidized in the inside pipe of a vertical double pipe heat exchanger. Bed porosities of 0.94-0.76, and apple juice concentrations of 12, 16, 18, and 20 Brix were tested. The new erosion model was developed based on an analogy between erosion and heat-transfer phenomenon. Experimental values of erosion rate were obtained for different operating conditions and compared with the values estimated by the model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.