Recurrent hemolytic uremic syndrome (recHUS) is a heterogeneous group of disorders. The pathogenesis of recHUS is not fully understood. recHUS has a high risk of development of terminal renal insufficiency and other sequelae. Abnormalities in complement factor H or in membrane-bound complement inhibitors with consecutive complement activation can be found in approximately 30 to 50% of the patients. Starting in 2001, we evaluated 42 patients with recHUS from five European countries (Germany, Austria, Hungary, Switzerland, and the Czech Republic). We measured the terminal complement complex (TCC) by an enzyme-linked immunosorbent assay using a neoepitope-specific anti-C9 antibody in 17 patients in plasma (native complement activation), serum (after coagulation), and zymosan-activated serum (Z-serum; after stimulation of coagulation). We compared the results to those of 16 healthy persons. In patients with recHUS (eight males, nine females) with a median age of 10.8 years, the TCC values were higher in plasma (0.57 versus 0.48 microg/mL; P = 0.04) and serum (3.1 versus 2.2 microg/mL) than in those of the control group, with a median age of 28.6 years (six males, 10 females) The TCC values in patients with low C3 compared with patients with normal C3 levels were even higher in plasma and serum, and the ratio was much lower. Children with recHUS have higher concentrations of TCC in plasma and serum. The ratio of Z-serum to serum showed significantly lower values in children with recHUS (96.01 versus 150.3; P = 0.01). These findings indicate a higher grade of complement activation and consumption in recHUS, suggesting that TCC may mediate cell toxicity. This may play an important role in the inferior outcome of these patients. The isolated substitution of factor H, or other complement inhibitors to block TCC formation, may represent useful therapies for these patients.
Background Ileus is common after elective colorectal surgery, and is associated with increased adverse events and prolonged hospital stay. The aim was to assess the role of non‐steroidal anti‐inflammatory drugs (NSAIDs) for reducing ileus after surgery. Methods A prospective multicentre cohort study was delivered by an international, student‐ and trainee‐led collaborative group. Adult patients undergoing elective colorectal resection between January and April 2018 were included. The primary outcome was time to gastrointestinal recovery, measured using a composite measure of bowel function and tolerance to oral intake. The impact of NSAIDs was explored using Cox regression analyses, including the results of a centre‐specific survey of compliance to enhanced recovery principles. Secondary safety outcomes included anastomotic leak rate and acute kidney injury. Results A total of 4164 patients were included, with a median age of 68 (i.q.r. 57–75) years (54·9 per cent men). Some 1153 (27·7 per cent) received NSAIDs on postoperative days 1–3, of whom 1061 (92·0 per cent) received non‐selective cyclo‐oxygenase inhibitors. After adjustment for baseline differences, the mean time to gastrointestinal recovery did not differ significantly between patients who received NSAIDs and those who did not (4·6 versus 4·8 days; hazard ratio 1·04, 95 per cent c.i. 0·96 to 1·12; P = 0·360). There were no significant differences in anastomotic leak rate (5·4 versus 4·6 per cent; P = 0·349) or acute kidney injury (14·3 versus 13·8 per cent; P = 0·666) between the groups. Significantly fewer patients receiving NSAIDs required strong opioid analgesia (35·3 versus 56·7 per cent; P < 0·001). Conclusion NSAIDs did not reduce the time for gastrointestinal recovery after colorectal surgery, but they were safe and associated with reduced postoperative opioid requirement.
An international team spanning 19 sites across 18 biopharmaceutical and in vitro diagnostics companies in the United States, Europe, and China, along with one regulatory agency, was formed to compare the precision and robustness of imaged CIEF (ICIEF) for the charge heterogeneity analysis of the National Institute of Standards and Technology (NIST) mAb and a rhPD-L1-Fc fusion protein on the iCE3 and the Maurice instruments. This information has been requested to help companies better understand how these instruments compare and how to transition ICIEF methods from iCE3 to the Maurice instrument. The different laboratories performed ICIEF on the NIST mAb and rhPD-L1-Fc with both the iCE3 and Maurice using analytical methods specifically developed for each of the molecules. After processing the electropherograms, statistical evaluation of the data was performed to determine consistencies within and between laboratory and outlying information. The apparent isoelectric point (pI) data generated, based on two-point calibration, for the main isoform of the NIST mAb showed high precision between laboratories, with RSD values of less than 0.3% on both instruments. The SDs for the NIST mAb and the rhPD-L1-Fc charged variants percent peak area values for both instruments are less than 1.02% across different laboratories. These results validate the appropriate use of both the iCE3 and Maurice for ICIEF in the biopharmaceutical industry in support of process development and regulatory submissions of biotherapeutic molecules. Further, the data comparability between the iCE3 and Maurice illustrates that the Maurice platform is a next-generation replacement for the iCE3 that provides comparable data.
Background Postoperative acute kidney injury (AKI) is a common complication of major gastrointestinal surgery with an impact on short- and long-term survival. No validated system for risk stratification exists for this patient group. This study aimed to validate externally a prognostic model for AKI after major gastrointestinal surgery in two multicentre cohort studies. Methods The Outcomes After Kidney injury in Surgery (OAKS) prognostic model was developed to predict risk of AKI in the 7 days after surgery using six routine datapoints (age, sex, ASA grade, preoperative estimated glomerular filtration rate, planned open surgery and preoperative use of either an angiotensin-converting enzyme inhibitor or an angiotensin receptor blocker). Validation was performed within two independent cohorts: a prospective multicentre, international study (‘IMAGINE’) of patients undergoing elective colorectal surgery (2018); and a retrospective regional cohort study (‘Tayside’) in major abdominal surgery (2011–2015). Multivariable logistic regression was used to predict risk of AKI, with multiple imputation used to account for data missing at random. Prognostic accuracy was assessed for patients at high risk (greater than 20 per cent) of postoperative AKI. Results In the validation cohorts, 12.9 per cent of patients (661 of 5106) in IMAGINE and 14.7 per cent (106 of 719 patients) in Tayside developed 7-day postoperative AKI. Using the OAKS model, 558 patients (9.6 per cent) were classified as high risk. Less than 10 per cent of patients classified as low-risk developed AKI in either cohort (negative predictive value greater than 0.9). Upon external validation, the OAKS model retained an area under the receiver operating characteristic (AUC) curve of range 0.655–0.681 (Tayside 95 per cent c.i. 0.596 to 0.714; IMAGINE 95 per cent c.i. 0.659 to 0.703), sensitivity values range 0.323–0.352 (IMAGINE 95 per cent c.i. 0.281 to 0.368; Tayside 95 per cent c.i. 0.253 to 0.461), and specificity range 0.881–0.890 (Tayside 95 per cent c.i. 0.853 to 0.905; IMAGINE 95 per cent c.i. 0.881 to 0.899). Conclusion The OAKS prognostic model can identify patients who are not at high risk of postoperative AKI after gastrointestinal surgery with high specificity. Presented to Association of Surgeons in Training (ASiT) International Conference 2018 (Edinburgh, UK), European Society of Coloproctology (ESCP) International Conference 2018 (Nice, France), SARS (Society of Academic and Research Surgery) 2020 (Virtual, UK).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.