Background: Skinfold thickness (SFT) and bioelectrical impedance (BIA) are readily available and commonly used techniques in patient monitoring for body composition analysis (BCA) in clinical practise. Another one, dual-energy X-ray absorptiometry (DEXA) method became popular in body composition analysis (BCA) in recent years. Its results have been reported to be quite accurate and precise, in comparison with in vivo or in vitro multiple component reference methods. The aim of the present study was to assess the degree of agreement between SFT and DEXA, and BIA and DEXA methods, in obese and nonobese patients. Methods: Body fat mass (FM) was measured in 16 nonobese (mean body mass index; BMI = 22.2 ± 2.2 kg/m2) and in 21 obese (BMI = 34.5 ± 6.1 kg/m2) women with DEXA, SFT, and BIA in the same morning. Results: Mean (± SD) FM (kg) was 16.3 ± 5.5, 15.0 ± 5.1, 14.7 ± 4.9 in nonobese subjects and 38.8 ± 10.1, 36.3 ± 10.0, 37.1 ± 12.0 in obese patients, by DEXA, SFT and BIA, respectively. Comparison of the DEXA-BIA and DEXA-STF methods showed high correlation in regression line analysis in nonobese subjects as, r2 = 0.93 and 0.89, respectively. Regression coefficents were 0.84 and 0.75 in obese patients. However, reanalysis of the data by the Bland and Altman method revealed an obvious lack of agreement between the DEXA-BIA and DEXA-SFT methods in obese patients. In addition, FM was underestimated by BIA and SFT as compared to DEXA in both of the study groups. Besides, better precision was obtained by DEXA method among the others. Conclusion: The SFT or BIA method would be preferred to monitor BCA in non-obese subjects in clinical routine. However, DEXA should be considered as the method of choice in obese patient monitoring, since reproducibility gains special importance, other than the accuracy in the context.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.