The generalizations of the Onsager model for the radial boundary layer and the Carrier-Maslen model for the end-cap axial boundary layer in a high-speed rotating cylinder are formulated for studying the secondary gas flow due to wall heating and due to insertion of mass, momentum and energy into the cylinder. The generalizations have wider applicability than the original Onsager and Carrier-Maslen models, because they are not restricted to the limit A 1, though they are restricted to the limit Re 1 and a high-aspect-ratio cylinder whose length/diameter ratio is large. Here, the stratification parameter A = mΩ 2 R 2 /(2k B T). This parameter A is the ratio of the peripheral speed, ΩR, to the most probable molecular speed, √ 2k B T/m, the Reynolds number Re = ρ w ΩR 2 /µ, where m is the molecular mass, Ω and R are the rotational speed and radius of the cylinder, k B is the Boltzmann constant, T is the gas temperature, ρ w is the gas density at wall, and µ is the gas viscosity. In the case of wall forcing, analytical solutions are obtained for the sixth-order generalized Onsager equations for the master potential, and for the fourthorder generalized Carrier-Maslen equation for the velocity potential. For the case of mass/momentum/energy insertion into the flow, the separation-of-variables procedure is used, and the appropriate homogeneous boundary conditions are specified so that the linear operators in the axial and radial directions are self-adjoint. The discrete eigenvalues and eigenfunctions of the linear operators (sixth-order and second-order in the radial and axial directions for the Onsager equation, and fourth-order and second-order in the axial and radial directions for the Carrier-Maslen equation) are determined. These solutions are compared with direct simulation Monte Carlo (DSMC) simulations. The comparison reveals that the boundary conditions in the simulations and analysis have to be matched with care. The commonly used 'diffuse reflection' boundary conditions at solid walls in DSMC simulations result in a non-zero slip velocity as well as a 'temperature slip' (gas temperature at the wall is different from wall temperature). These have to be incorporated in the analysis in order to make quantitative predictions. In the case of mass/momentum/energy sources within the flow, it is necessary to ensure that the homogeneous boundary conditions are accurately satisfied in the simulations. When these precautions are taken, there is excellent agreement between analysis and simulations, to within 10 %, even when the stratification parameter is as low as 0.707, the Reynolds number is as low as 100 and the aspect ratio (length/diameter) of the cylinder is as low as 2, and the secondary flow velocity is as high as 0.2 times the maximum base flow velocity. The predictions of the generalized models are also significantly better than those of the original Onsager † Email address for correspondence: kumaran@chemeng.iisc.ernet.in 110 S. Pradhan and V. Kumaran and Carrier-Maslen models, which are restricted to thin bou...
An analysis is carried out for the free convective flow of an electrically conducting micropolar fluid through permeable stretching sheet in the presence of porous medium. Inclusion of thermal radiation to the energy equation enhances the thermal properties of polar fluid. In addition to that the radiation absorption parameter occurs due to the interaction of solutal concentration difference also considered in the heat transfer equation. Suitable similar transformation is used to convert the governing partial differential equations to ordinary differential equations. Furthermore, though analytical solutions of these complex nonlinear coupled equations are more complicated therefore, numerical solution such as Runge‐Kutta fourth order method associated with shooting technique is adopted. Behavior of characterizing parameters for the flow phenomena are presented via graphs and computed values of physical quantities of interest are obtained and shown in tabular form. Present result validates with that of earlier results in particular case which confirms the existence of present solution methodology. However, the main findings of contributing parameters are laid down as; angular velocity profile contributes a dual character from the point of contact at the middle of the channel. Fluid temperature is affected by the inclusion of absorption coefficient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.