Polymerase chain reaction, although an expensive method for the detection of human Plasmodium spp., is still considered the finest for the diagnosis of malaria. The conventional diagnostic PCR is an inexpensive process but consumes a lot of time, reagents and lacks sensitivity. On the other hand, real-time PCR assays currently being used are mostly probe-based expensive methods and sometimes not feasible to detect all the species in a single amplification reaction condition. Here we have established a real-time PCR method that is time and cost effective with a single protocol to detect and distinguish five human Plasmodium species using the existing primers efficiently. The primers used here are being used in the conventional method and the sensitivity as well as specificity of this method has also been immensely improved (100%). The lower limit of detection for Plasmodium falciparum, Plasmodium vivax and Plasmodium malariae are 0.064 parasites/µL, 1.6 parasites/µL, and 0.32 parasites/µL respectively and no cross reactivity was observed. Besides, we have analyzed melt curves that can be used for further species confirmation and validation purposes using multiplex systems. This method, therefore, can be considered as an alternative to the existing lineup for molecular diagnosis of malaria in endemic countries.
Introduction: The persistent increase of resistance to existing antimalarials underscores the needs for new drugs. Historically, most of the successful antimalarial are derived from plants. The leaves of the S. cymosum is one of the plant materials used by traditional healers in malaria-endemic areas in Bangladesh for treatment of malaria. Here, we investigated the crude extract and its fractions against chloroquine (CQ)-sensitive 3D7, CQ-resistant Dd2, and artemisinin (ART)-resistant IPC 4912 Mondulkiri strains of Plasmodium falciparum.
Methodology: The antimalarial activities were tested using HRP II based in-vitro antimalarial drug sensitivity ELISA described by WWARN and half inhibitory concentrations (IC50) were calculated by non-linear regression analysis using GraphaPad Prism. The cytotoxicity of the crude methanolic extract was assessed using the MTT assay on Vero cell line.
Results: The methanolic crude extract revealed promising activity against 3D7 (IC50 6.28 µg/mL), Dd2 (IC50 13.42 µg/mL), and moderate activity against IPC 4912 Mondulkiri (IC50 17.47 µg/mL). Among the fractionated portions, the chloroform fraction revealed highest activity against IPC 4912 Mondulkiri (IC50 1.65 µg/mL) followed by Dd2 (1.73 µg/mL) and 3D7 (2.39 µg/mL). The crude methanolic extract also demonstrated good selectivity with the selectivity indices of > 15.92, > 7.45, and > 6.91 against 3D7, Dd2, and IPC 4912, respectively when tested against Vero cell line.
Conclusions: This is the first report on S. cymosum for its putative antimalarial activity, and is imperative to go for further phytochemical analyses in order to investigate possible novel antimalarial drug compound(s).
Accurate diagnosis at the right moment is the prerequisite for treatment of any disease. Failure to correctly diagnose a disease can result in highly detrimental effects, unmistakably a crucial factor during the COVID-19 pandemic. RT-PCR is the gold standard for COVID-19 detection while there are other test procedures available, such as LAMP, X-Ray, and ELISA. However, these tests are expensive, require sophisticated equipment and a highly trained workforce, and multiple hours or even days are often required to obtain the test results. A rapid and cheap detection system can thus render a solution to the screening system on a larger scale and be added as an aid to the current detection processes. Recently, some rapid antigen-based COVID-19 tests devices have been developed and commercialized. In this study, we evaluated the clinical performance of a new rapid detection device (OnSite® COVID-19 Ag Rapid Test by CTK Biotech Inc., Poway, CA, USA) on COVID-19 symptomatic patients (n = 380). The overall sensitivity and specificity were 91.0% (95% CI: 84.8–95.3%) and 99.2% (95% CI: 97.1–99.9), against gold standard RT-PCR. The kit was capable of detecting patients even after 06 days of onset of symptoms and the sensitivity can be maximized to 98% in samples with an average RT-PCR Ct ≤ 26.48, demonstrating a high potential of the kit for clinical diagnosis of symptomatic patients in healthcare facilities.
There are several methods for the diagnosis of coronavirus disease 2019 (COVID-19), and the choice of methods depends mostly on the resources and level of sensitivity required by the user and health care providers. Still, reverse transcription polymerase chain reaction (RT-PCR) has been chosen as the best method using direct naso-oropharyngeal swabs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.