Pulmonary hypertension in pregnancy carries a high maternal and fetal morbidity, and mortality. In recent times, there has been significant progress in the field of pulmonary vascular disease with a better understanding of the disease and novel targeted therapies, which have ultimately resulted in improved outcomes. In addition, the development of an individualized and multidisciplinary approach to the management of pulmonary hypertension during pregnancy is essential for improved outcomes.
Shoulder dystocia is a term that evokes terror and fear among many physicians, midwives, and health care providers as they recollect at least 1 episode of shoulder dystocia in their careers. Shoulder dystocia can result in significant maternal and neonatal complications. Because shoulder dystocia is an urgent, unanticipated, and uncommon event with potentially catastrophic consequences, all practitioners and health care teams must be well-trained to manage this obstetric emergency. Preparation for shoulder dystocia in a systematic way, through standardization of process, practicing team-training and communication, along with technical skills, through simulation education and ongoing quality improvement initiatives will result in improved outcomes.
BACKGROUND: Tocodynamometry is a common, noninvasive tool used to measure contraction frequency; however, its utility is often limited in patients with obesity. An intrauterine pressure catheter provides a more accurate measurement of uterine contractions but requires ruptured membranes, limiting its utility during early latent labor. Electrical uterine myography has shown promise as a noninvasive contraction monitor with efficacy similar to that of the intrauterine pressure catheter; however, its efficacy has not been widely studied in the obese population. OBJECTIVE: This study aimed to validate the accuracy of electrical uterine myography by comparing it with tocodynamometry and intrauterine pressure catheters among laboring patients with obesity. STUDY DESIGN: This was a prospective observational study from February 2017 to April 2018 of patients with obesity, aged 18 years or older, who were admitted to the labor unit with viable singleton pregnancies and no contraindications for electromyography. Patients were monitored simultaneously with electrical myography and tocodynamometry or intrauterine catheter for more than 30 minutes. Two blinded obstetricians reviewed the tracings. The outcomes of interest were continuous and interpretable tracing, number of contractions, and timing and duration of contractions, interpreted as point estimates and associated 95% confidence intervals. RESULTS: A total of 110 patients were enrolled (65 tocodynamometry, 55 intrauterine catheter). Electrical myography was significantly more interpretable during a 30-minute tracing (P=.001) and detected 39% more contractions than tocodynamometry (P<.0001; 95% confidence interval, 23%−57%), whereas there was no difference in the interpretability of tracings or number of contractions between electrical myography and an intrauterine catheter (P=.16; 95% confidence interval, −0.19 to 1.19). Patients who underwent simultaneous monitoring preferred the electrical myography device over tocodynamometry. CONCLUSION: Electrical uterine myography is superior to tocodynamometry in the detection of intrapartum uterine contraction monitoring and comparable with internal contraction monitoring.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.