Background: Cardiac magnetic resonance imaging (CMR) allows for detection of fibrosis in hypertrophic cardiomyopathy (HCM) by quantification of the extracellular volume fraction (ECV). Hypothesis/Objectives: To quantify native T1 mapping and ECV in cats. We hypothesize that native T1 mapping and ECV will be significantly increased in HCM cats compared with healthy cats. Animals: Seventeen healthy and 12 preclinical HCM, age-matched, client-owned cats. Methods: Prospective observational study. Tests performed included indirect blood pressure, CBC, biochemical analysis including total thyroid, urinalysis, transthoracic echocardiogram, and CMR. Cats were considered healthy if all tests were within normal limits and a diagnosis of HCM was determined by the presence of left ventricular concentric hypertrophy ≥6 mm on echocardiography. Results: There were statistically significant differences in LV mass (healthy = 5.87 g, HCM = 10.3 g, P < .0001), native T1 mapping (healthy = 1122 ms, HCM = 1209 ms, P = .004), and ECV (healthy = 26.0%, HCM = 32.6%, P < .0001). Variables of diastolic function including deceleration time of early diastolic transmitral flow (DTE), ratio between peak velocity of early diastolic transmitral flow and peak velocity of late diastolic transmitral flow (E : A), and peak velocity of late diastolic transmitral flow
ObjectiveTo assess the prognostic value of neutrophil-to-lymphocyte ratio (NLR) for cardiac death in cats with hypertrophic cardiomyopathy.Study DesignProspective observation study.AnimalsNinety-six client-owned cats.MethodsComplete blood count samples were collected from 38 healthy and 58 cats with hypertrophic cardiomyopathy (HCM), and the NLR ratios were analyzed. All cats had echocardiographic measurements performed on the same day as blood collection. Spearman rank correlation was used to assess the relationship between echocardiographic measurements and NLR. Long-term outcome data were obtained, and time to cardiac death and variables associated with cardiac death were analyzed using Kaplan–Meier survival curves and Cox proportional hazards models, respectively.ResultsThe NLR was significantly higher in cats with confirmed congestive heart failure. When evaluating HCM patients, cats in the third NLR tertile had a significantly higher risk of cardiac death with a hazard ratio of 10.26 (95% CI: 1.84–57.14; p = 0.0001) when compared with that of patients in the first tertile. NLR was significantly associated with echocardiographic measures of left atrial size, left auricular function, the presence of left atrial spontaneous echo contrast (SEC), and thrombus formation.Conclusions and Clinical RelevanceIncreased NLR is a negative prognostic indicator in cats with HCM.
Objectives The purpose of this study was to evaluate the effects of oral trazodone on echocardiographic variables, heart rate (HR) and blood pressure (BP) in healthy cats. Methods Client-owned domestic cats between 2 and 8 years of age were recruited. Cats were considered healthy based on physical examination, complete blood count, blood chemistry profile, urinalysis, total thyroxine concentration, non-invasive BP measurement by Doppler method and a screening transthoracic echocardiogram with simultaneous electrocardiogram. Echocardiographic variables assessed pre-trazodone and 90–120 mins post-trazodone (50 mg PO) included left ventricular internal diameter in systole and diastole, interventricular septal and left ventricular free-wall thickness in systole and diastole, left atrial size, left auricular function and left ventricular diastolic function assessed by spectral Doppler transmitral and pulmonary venous flow velocities, and tissue Doppler profiles. Mean echocardiographic and hemodynamic variables were calculated for pre- and post-trazodone examinations for each cat. Pre- and post-trazodone variables were analyzed with a paired t-test with significance set at P <0.05. Results Twelve healthy cats were evaluated. Trazodone was administered to all cats and a sedative effect was observed. There were no clinically significant differences in any echocardiographic variables post-trazodone administration. Systolic BP was significantly decreased after trazodone ( P = 0.001) with no significant change in HR. Conclusions and relevance Trazodone did not alter echocardiographic variables, in a clinically relevant manner, in this group of healthy cats. Trazodone may aid in obtaining transthoracic echocardiograms without affecting HR or echocardiographic variables but may significantly lower BP in healthy cats.
Theophylline is used in canine medicine for the management of chronic bronchitis and bradyarrhythmias, yet no species-validated commercial products are available.This study reports the single-dose and multidose pharmacokinetics and safety of a modified, compounded theophylline (MCT) product readily available from a wellestablished, USP-compliant compounding pharmacy, which may be a suitable and reliable source for theophylline for dogs. Eleven dogs underwent serial plasma theophylline measurement following 10 mg/kg MCT PO. After a 7 days washout, dogs received 10 mg/kg MCT PO q12h and serial plasma theophylline quantification was repeated after the ninth dose. Dogs were monitored for potential adverse effects. For the nine dogs that completed the study, plasma theophylline concentrations were between 5 and 30 μg/ml for 91 +/− 15% of the dosing interval. There was no significant difference in half-life between single-dose and multidose administration. The most common adverse effects reported were mild and included agitation, excitement, and increased activity. The results of this study support the use of 10 mg/kg MCT administered twice daily as a starting dosage in dogs. This regimen appears safe, achieves appropriate plasma drug concentrations in most dogs, and does not cause significant changes in pharmacokinetic properties at steady state. Because compounded drugs do not undergo consistent testing for identity, quality, strength, purity, and stability, results of research described in reports using compounded products may not be reproducible.
OBJECTIVE To compare measurements of left ventricular volume and function derived from 2-D transthoracic echocardiography (2DE), transesophageal echocardiography (TEE), and the ultrasound velocity dilution cardiac output method (UDCO) with those derived from cardiac MRI (cMRI) in healthy neonatal foals. ANIMALS 6 healthy 1-week-old Standardbred foals. PROCEDURES Foals were anesthetized and underwent 2DE, TEE, and cMRI; UDCO was performed simultaneously with 2DE. Images acquired by 2DE included the right parasternal 4-chamber (R4CH), left apical 4- and 2-chamber (biplane), and right parasternal short-axis M-mode (M-mode) views. The longitudinal 4-chamber view was obtained by TEE. Measurements assessed included left ventricular end-diastolic volume (LVEDV), end-systolic volume (LVESV), ejection fraction, stroke volume (LVSV), cardiac output (CO), and cardiac index (CI). Bland-Altman analyses were used to compare measurements derived from biplane, R4CH, and M-mode images and UDCO with cMRI-derived measurements. Repeatability of measurements calculated by 3 independent reviewers was assessed by the intraclass correlation coefficient. RESULTS Compared with cMRI, all 2DE and TEE modalities underestimated LVEDV and LVESV and overestimated ejection fraction, CO, and CI. The LVSV was underestimated by the biplane, R4CH, and TEE modalities and overestimated by UDCO and M-mode methods. However, the R4CH-derived LVSV, CO, and CI were clinically comparable to cMRI-derived measures. Repeatability was good to excellent for measures derived from the biplane, R4CH, M-mode, UDCO, and cMRI methods and poor for TEE-derived measures. CONCLUSIONS AND CLINICAL RELEVANCE All assessed modalities yielded clinically acceptable measurements of LVEDV, LVESV, and function, but those measurements should not be used interchangeably when monitoring patient progress.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.