These results suggested that oral cryotherapy could effectively prevent stomatitis caused by high-dose melphalan, and we recommend that it should be incorporated into the conditioning regimen with high-dose melphalan.
We previously reported the efficacy of oral cryotherapy for the prevention of high-dose melphalan-induced stomatitis. The purpose of this study was to evaluate whether the further shortening of the duration of oral cryotherapy could minimize its side effects while sparing its efficacy. Seventeen consecutive recipients of allogeneic hematopoieic stem cell transplant conditioned with high-dose melphalan in combination with fludarabine alone or with fludarabine and additional radiation were enrolled in the study. The severity of stomatitis was graded according to the National Cancer Institute-Common Toxicity Criteria. Patients were kept on oral cryotherapy shortly before, during, and for additional 30 min after the completion of melphalan administration (60-min oral cryotherapy). Patients who were also enrolled in our previous study received the same type of oral cryotherapy but for additional 90 min after the completion of melphalan administration (120-min oral cryotherapy), and they served as controls. Only 2 (11.8%) of 17 patients receiving 60-min oral cryotherapy and 2 (11.1%) of 18 patients receiving 120-min oral cryotherapy developed grade 2 or 3 stomatitis, respectively. The difference between groups was not statistically significant (P = 0.677). The incidence of unpleasant symptoms such as chills and nausea during oral cryotherapy decreased significantly with 60-min oral cryotherapy, as compared with that associated with 120-min oral cryotherapy (P < 0.01). These results suggest that 60-min oral cryotherapy is as effective as 120-min oral cryotherapy at preventing high-dose melphalan-induced stomatitis, and shorter treatment might have contributed to relieve patient discomfort during oral cryotherapy.
High-dose cytarabine is one of the major components of the conditioning regimen for hematopoietic stem cell transplantation (HSCT), and frequently causes severe oral mucositis. We have recently demonstrated that cytarabine is excreted into the saliva in patients receiving high-dose cytarabine, and proposed that it might locally and directly contribute to the development of oral mucositis. Therefore, this study was performed to assess whether removing the excreted cytarabine in the saliva by intensive mouth rinse during high-dose cytarabine infusion could reduce the incidence of oral mucositis. Fifteen patients with hematologic malignancies undergoing allogeneic HSCT who received total body irradiation (12 Gy) and high-dose cytarabine at a dose of 3 g/m(2) every 12 h for 4 days as a conditioning were evaluated. Patients were instructed to rinse their mouths using ice-cold water every 10 min, starting simultaneously with the 2-h cytarabine infusion and continuing up to 1 h after completion of each infusion. Oral mucositis was graded on a daily basis according to the National Cancer Institute, Common Toxicity Criteria. Thirty-five patients who previously underwent the same conditioning without mouth rinse served as controls. The incidence of Grades 2-3 and Grade 3 oral mucositis was significantly reduced in patients who performed mouth rinse as compared with the controls (40 vs. 80%, P = 0.009; 0 vs. 25. 7%, P = 0.02). In conclusion, mouth rinse during and shortly after high-dose cytarabine infusion could be an effective and inexpensive measure in reducing the incidence of moderate to severe oral mucositis caused by high-dose cytarabine. This finding strongly suggests the role of cytarabine excretion in the saliva in the development of cytarabine-associated oral mucositis.
A surface plasmon resonance (SPR) sensor chip fabricated with a comb-shaped microelectrode array to supply alternating current (AC) voltage is reported. The chip induces circulating flow near the surface (i.e., AC electroosmosis). The circulating flow provides a mixing effect, which enhances the binding of the analyte molecules. We evaluated the SPR characteristics of the chip and demonstrated an improvement in protein binding to the chip surface. SPR sensor chips with comb-shaped microelectrodes were fabricated using standard UV lithography. Sensing experiments were conducted using a standard Kretschmann-type SPR measurement system. To demonstrate the mixing effect of AC electroosmosis, we evaluated the binding of immunoglobulin G molecules onto the sensor surface where anti-immunoglobulin G antibodies were covalently immobilized. The result indicates that the amount of binding increases by a factor of 1.7 above that achieved by using a conventional chip, suggesting enhancement of the protein signal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.