BackgroundDespite evidence against the use of antimicrobials for asymptomatic bacteriuria (ASB), they are frequently prescribed leading to unnecessary adverse events. Prior studies have shown that reducing unnecessary urine cultures (UCs) results in decreased antimicrobial utilisation for ASB. Emergency departments (EDs) submit the largest volume of UCs, yet efforts to limit overordering in this patient setting have had limited success.MethodsA new two-step model of care for urine collection, using a novel UC collection container, was implemented in the ED of a large community hospital. The collection system contains a preservative allowing UCs to be held at room temperature for up to 48 hours before processing. UCs were collected by front-line staff, but only processed in the microbiology lab if requested by ED physicians after clinical assessment.ResultsFollowing implementation there was a decrease in the percentage of weekly ED visits associated with a processed UC (5.97% vs 4.68%, p<0.001), a decrease in the percentage of monthly ED visits requiring a callback for positive urine culture (1.84% to 1.12%, p<0.001) and a decrease in antimicrobial prescriptions for urinary indication among admitted patients (20.6% to 10.9%, p<0.01). There was a false omission rate of 1.35% (95% CI 0.7% to 2.2%), yet no identified cases of untreated urinary tract infection (UTI), or significant change in repeat ED visits or ED length of stay.ConclusionsChanging to two-step urine culture ordering in the ED resulted in a decrease in UCs processed, callbacks for positive results and antimicrobial use without evidence of untreated UTIs. This model of care has strong potential to improve the use of hospital resources while minimising detection and inappropriate treatment of ASB.
We evaluated the operating characteristics of 2 comparably trained dogs as a “point-of-care” diagnostic tool to detect toxin gene-positive Clostridium difficile. Although each dog could detect toxin gene-positive C difficile in stool specimens with sensitivities of 77.6 and 92.6 and specificities of 85.1 and 84.5, respectively, interrater reliability is only modest (Cohen’s kappa 0.52), limiting widespread application.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.