Abstract. Autologous arteriovenous fistulas (AVF) have the best 5-yr patency and the lowest complication rate among hemodialysis vascular accesses. However, maturation requirements to optimize survival are unknown. A longitudinal cohort study was conducted to ascertain risk factors for failure, maturation time, and survival of the first AVF. All patients who initiated hemodialysis between January 1, 1997, and December 31, 2002, in three centers were included in this study. Analysis was restricted to patients who received an AVF. Cox regression was used to estimate the association between predictors of interest and primary and secondary AVF survival. Of the 535 patients enrolled (mean age, 66.5 yr; 57.8% male; 26.7% diabetic), 513 (96%) received an AVF. Patients who initiated with catheters (47%) cannulated their AVF earlier (median maturation period, 0.78 versus 1.80 mo; P Ͻ 0.001). Median primary and secondary survivals were longer than 50 and 72 mo, respectively. After adjustment for confounding factors, cardiovascular disease (hazard ratio [HR], 1.84; 95% confidence interval [CI], 1.26 to 2.67), utilization earlier than 1 mo after placement (HR, 1.94; 95% CI, 1.34 to 2.82), and referral within 3 mo of dialysis start (HR, 1.55; 95% CI, 1.04 to 2.32) were associated with a reduction in primary AVF survival. Presence of cardiovascular disease (HR, 2.21; 95% CI, 1.38 to 3.55), maturation time Ͻ15 d (HR, 2.12; 95% CI, 1.20 to 3.73), and presence of catheters at hemodialysis initiation (HR, 1.79; 95% CI, 1.13 to 2.84) were associated with lower secondary AVF survival. It is concluded that cardiovascular disease, late referral, temporary catheters, and early cannulation are associated with impaired AVF survival. It is recommended that AVF be allowed to mature at least 1 mo before cannulation.Creation and maintenance of a well-functioning vascular access (VA) remains one of the most challenging problems in delivering adequate hemodialysis (HD) therapy. As compared with arteriovenous grafts and permanent cuffed central venous catheters, native arteriovenous fistulas (AVF) are viewed as being superior, because of the much smaller number of procedures associated with use and longer overall survival (1). However, AVF are not readily utilizable after placement, and early cannulation has been shown to be associated with shorter survival (2). Indeed, the optimal maturation period to make cannulation easier and improve AVF survival is not established, although it is common practice to delay utilization after insertion to allow enlargement and "arterialization" of the vein. This maturation process is expected to result in adequate blood flow through the fistula and in lower risk of local hemorrhage at the cannulation site, wall damage, fibrosis, and final occlusion. The current National Kidney Foundation's Dialysis Outcomes Quality Initiative guidelines endorse this practice and recommend that initial use be delayed for at least 4 wk after surgery, although this guidance is based on opinion (3), and a shorter maturation time ...
In the last years, the number of hemodialysis (HD) patients with erythropoietin (rHuEPO) resistance is increasing. Probably, central venous catheters (CVCs) contribute to this resistance by inducing inflammation and oxidative stress. This study was aimed to compare vitamin E-bonded dialyzer (PSVE) versus polyethersulfone membrane. Sixteen subjects with CVCs were included in a prospective two-arm crossover 12-month study. The primary endpoints were the rHuEPO requirement and the erythropoiesis-stimulating agents (ESA) index, which was defined by the ratio between weekly EPO dosage (IU/kg/week) and Hb levels (g/dl). The mean dosages of rHuEPO to maintain hemoglobin between 10.5 and 12 g/dl were 135 ± 59 and 101 ± 57 IU/kg/week with polysulfone and PSVE, respectively (P = 0.14). The ESA indexes were 12.1 ± 5.2 and 8.7 ± 5.2 (P < 0.0001) with polysulfone and PSVE, respectively. A trend towards consensual changes in protein glycoxidation, antioxidant, and inflammatory markers was observed. In conclusion, the study suggests a role for PSVE in the reduction of ESA index in HD patients with CVCs.
Optimization of hemodialysis treatment parameters and the characteristics of the dialyzer are crucial for short- and long-term outcome of end stage renal disease patients. The new high-flux membrane Helixone® in the dialyzer of the FX series (Fresenius Medical Care, Germany) has interesting features, such as the relationship of membrane thickness and capillary diameter which increases middle molecule elimination by convection, as well as higher capillary packing and microondulation to improve the dialysate flow and distribution. Blood flow, dialysate flow and surface area are the main determinants of the performance of a dialyzer, however the impact of each parameter on small and middle molecule clearance in high flux dialysis has not been well explored. In order to find the best treatment condition for the new dialyzer series, we evaluated urea, creatinine, phosphate clearances and reduction rate of ß2-microglobulin in ten stable patients treated with different blood flows (effective Qb 280 and 360 ml/min), dialysate flow (Qd 300 or 500 ml/min) and dialyzer surfaces (1.4 and 2.2 m2, FX60 or FX100). KoA and Kt/V were also calculated. Blood flow, dialysate flow and surface area demonstrated a significant and independent effect on clearance of urea, creatinine and phosphate, as well as on Kt/V. Small solute clearance was stable over the treatment. In contrast to small solutes, reduction rate of ß2-microglobulin was related to increasing dialyzer surface only. The new dialyzer design of the FX series proves highly effective due to improved dialysate distribution and reduced diffusive resistance as shown by the small solute clearance. A high reduction rate of ß2-microglobulin is favored by improved fiber geometry and pore size distribution. These findings have potential long-term benefits for the patient
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.