Aims The GermAn Laser Lead Extraction GallerY (GALLERY) is a retrospective, national multicentre registry, investigating the safety and efficacy of laser lead extraction procedures in Germany. Methods and results Twenty-four German centres that are performing laser lead extraction have participated in the registry. All patients, treated with a laser lead extraction procedure between January 2013 and March 2017, were consecutively enrolled. Safety and efficacy of laser lead extraction were investigated. A total number of 2524 consecutive patients with 6117 leads were included into the registry. About 5499 leads with a median lead dwell time of 96 (62–141) months were treated. The mean number of treated leads per patient was 2.18 ± 1.02. The clinical procedural success rate was 97.86% and the complete lead removal was observed in 94.85%. Additional extraction tools were used in 6.65% of cases. The rate of procedural failure was 2.14% with lead age ≥10 years being its only predictor. The overall complication rate was 4.32%, including 2.06% major and 2.26% minor complications. Procedure-related mortality was 0.55%. Female sex and the presence of abandoned leads were predictors for procedure-related complications. The all-cause in-hospital mortality was 3.56% with systemic infection being the strongest predictor, followed by age ≥75 years and chronic kidney disease. Conclusion In the GALLERY, a high success- and low procedure-related complication rates have been demonstrated. In multivariate analysis, female sex and the presence of abandoned leads were predictors for procedure-related complications, while the presence of systemic infection, age ≥75 years, and chronic kidney disease were independent predictors for all-cause mortality.
Introduction Long‐term efficacy and safety are uncertain in patients with cardiac implantable electronic devices (CIED) and transvenous leads (TVL) undergoing radiofrequency catheter ablation of atrial fibrillation (AF). Thus, we assessed the outcome of AF ablation in those patients during long‐term follow‐up using continuous atrial rhythm monitoring (CARM). Methods and Results A total of 190 patients (71.3 ± 10.7 years; 108 (56.8% men) were included in this study. At index procedure 81 (42.6%) patients presented with paroxysmal AF and 109 (57.4%) with persistent AF. The ablation strategy included pulmonary vein isolation in all patients and biatrial ablation of complex fractionated electrograms with additional ablation lines, if appropriate. AF recurrences were assessed by CARM‐ and CIED‐related complications by device follow‐up. After a mean follow‐up of 55.4 ± 38.1 months, freedom of AF was found in 86 (61.4%) and clinical success defined as an AF burden less than or equal to 1% in 101 (72.1%) patients. Freedom of AF was reported in 74.6% and 51.9% (P = 0.006) and clinical success in 89.8% and 59.3% (P < 0.001) of patients with paroxysmal and persistent AF, respectively. In 3 of 408 (0.7%) ablation procedures, a TVL malfunction occurred within 90 days after catheter ablation. During long‐term follow‐up 9 (4.7%) patients showed lead dislodgement, 2 (1.1%) lead fracture, and 2 (1.1%) lead insulation defect not related to the ablation procedure. Conclusion Our findings using CARM demonstrate long‐term efficacy and safety of radiofrequency catheter ablation of AF in patients with CIED and TVL.
The new GlideLight high-frequency laser sheath allows for a high safety and efficacy in extraction of chronically implanted pacemaker- and implantable cardioverter-defibrillator leads.
Introduction:The prevalence of obesity is increasing. However, data on the periprocedural complication rate of catheter ablation for arrhythmia in patients stratified by body mass index (BMI) are scarce.Methods: This study included 1000 consecutive patients (age 62.0 ± 14.4 years) undergoing catheter ablation for cardiac arrhythmia. The primary study endpoint was any periprocedural major complication (cardiac tamponade, pseudoaneurysm, arteriovenous fistula, transient ischemic attack, stroke, valve damage, myocardial infarction, or death).Results: The mean BMI was 27.6 ± 5.1 kg/m 2 and the majority of patients were overweight (BMI 25.0-29.9 kg/m 2 , 43.4%). A BMI of 30.0-34.9 kg/m 2 (Class I obesity) was present in 177 (17.7%) of patients, a BMI of 35.0-39.9 kg/m 2 (Class II obesity) in 67 (6.7%), and a BMI ≥ 40 kg/m 2 (Class III obesity) in 16 (1.6%). There were 31 major complications (3.1%) and one fatality (0.1%) due to terminal heart failure in a patient undergoing palliative ventricular tachycardia ablation. There was no significant impact of the BMI on the rate of major complications (p = .495).Compared to normal weight patients, odds ratios for complications in overweight patients, as well as Class I, II, and III obesity were 1.1 (95% confidence interval (CI):
OBJECTIVES Transvenous coronary sinus leads are considered to be the gold standard for cardiac resynchronization therapy (CRT). However, in patients with abnormal coronary vein anatomy, the epicardial leads can be an alternative. Data comparing durability and performance of these 2 lead types are limited. In order to provide clarity, we investigated patients receiving CRT system in our centre. METHODS One thousand and fifty-three consecutive patients scheduled for CRT implantation were retrospectively analysed. From these, 895 received transvenous coronary sinus and 158 epicardial left ventricular (LV) leads. Lead-specific as well as LV functional parameters have been evaluated in 60 months’ follow-up. RESULTS Technical characteristics (pacing threshold, impedance and sensing) of both lead types remained stable during the whole observation period. Whereas an early revision (<6 month) was noted in 5.4% of transvenous leads, no reintervention has been necessary for epicardial leads. During the 5-year observation period, a lead revisions rate of 10.2% for transvenous leads and 1.9% for epicardial leads were detected. Regarding CRT efficacy, excellent results were achieved for both electrode types. In both groups, a statistically significant reduction of New York Heart Association class (2.85–2.13 and 2.96–2.09), increase in left ventricular ejection fraction (24.6–32.6% and 27.2–34.6%), reduction of left ventricular end-systolic diameter/left ventricular end-diastolic diameter and reduction in degree of mitral valve insufficiency could be observed over the time. CONCLUSIONS Our data demonstrate safety and functional efficacy of both transvenous and epicardial leads. Moreover, in long-term follow-up, a commendable durability and performance were found for both lead types. Thus, epicardial leads represent a good alternative when transvenous implantation fails.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.