The proposed measure provides more reliable statistics on contour comparisons. From the statistics, specific local and global distances can be extracted. Bidirectional local distance is a reliable distance measure in comparing two- or three-dimensional organ segmentations.
Rigid-body image registration using our SWMI-GW and SWMI-SOI as cost functions can achieve better registration results in (a) designated image region(s) as well as faster convergence. With the theoretical foundation established, we believe SWMI could be extended to larger clinical testing.
This article proposes quantitative analysis tools and digital phantoms to quantify intrinsic errors of deformable image registration (DIR) systems and establish quality assurance (QA) procedures for clinical use of DIR systems utilizing local and global error analysis methods with clinically realistic digital image phantoms. Landmark-based image registration verifications are suitable only for images with significant feature points. To address this shortfall, we adapted a deformation vector field (DVF) comparison approach with new analysis techniques to quantify the results. Digital image phantoms are derived from data sets of actual patient images (a reference image set, R, a test image set, T). Image sets from the same patient taken at different times are registered with deformable methods producing a reference DVFref. Applying DVFref to the original reference image deforms T into a new image R'. The data set, R', T, and DVFref, is from a realistic truth set and therefore can be used to analyze any DIR system and expose intrinsic errors by comparing DVFref and DVFtest. For quantitative error analysis, calculating and delineating differences between DVFs, 2 methods were used, (1) a local error analysis tool that displays deformation error magnitudes with color mapping on each image slice and (2) a global error analysis tool that calculates a deformation error histogram, which describes a cumulative probability function of errors for each anatomical structure. Three digital image phantoms were generated from three patients with a head and neck, a lung and a liver cancer. The DIR QA was evaluated using the case with head and neck.
Composite plans created from different image sets are generated through Deformable Image Registration (DIR) and present a challenge in accurately presenting uncertainties, which vary with anatomy. Our effort focuses on the application of Fuzzy Set theory to provide an accurate dose representation of such a composite treatment plan. The accuracy of the DIR is generally verified through geometrical visual checks, including the confirmation of the corresponding anatomies with edge features, such as bone or organ boundaries. However, the remaining volume of the image (mostly soft tissues) has few significant image features and therefore greater uncertainty. We fuzzified the deformation vector and derived a Fuzzy composite dose. The fuzzification was implemented using Gaussian functions based on the varying uncertainties in the DIR. After establishing the theoretical basis for this new approach, we present two-and three-dimensional examples as proof-of-concept. Using Fuzzy Set theory, composite dose plans displaying localitybased uncertainties were successfully created, providing information previously unavailable to clinicians. Previous to Fuzzy Set dose presentations, clinicians had no measure of confidence in the accuracy of a composite dose plan. Using fuzzified composite dose presentations, clinicians can determine a safe additional dose to previously treated anatomy. This will possibly increase the treatment success rate and reduce the rate of complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.