Our aims were to identify potential differences in muscle mechanical properties (MMPs) of cervical and lumbar tissues and in spinal range of motion (ROM) between patients with acute low back pain (LBP) or acute neck pain (NP) and healthy controls, and to identify if ROMs and MMPs are able to identify subjects among the three groups. Clinical variables (pain, disability, fear of movement, kinesiophobia, quality of life), MMPs and ROMs were obtained in 33 subjects with acute LBP, 33 with acute NP, and 33 healthy control subjects. Between-groups differences and explanatory models to discriminate groups depending on MMPs and ROMs were calculated. The results showed that cervical tone was higher in patients with acute NP than in controls, while cervical decrement was higher in both spinal pain groups. Patients with acute NP showed reduced cervical flexion when compared to acute LBP and control groups, and also cervical rotation, but just against controls. Furthermore, lumbar flexion was reduced in patients with acute LBP when compared to those with acute NP. Cervical decrement was able to discriminate spinal pain individuals from controls in a multinominal regression (R2: Cox–Snell estimation = 0.533; Nagelkerke estimation = 0.600). Lumbar flexion differentiated patients with acute LBP and controls, whereas cervical flexion differentiated patients with acute NP and controls. This study supports a tendency of the affectation of other spinal regions when only one is affected.
Objective: This study aimed to determine the validity and reliability of Inertial Measurement Units (IMUs) for the assessment of craniocervical range of motion (ROM) in patients with cerebral palsy (CP). Methods: twenty-three subjects with CP and 23 controls, aged between 4 and 14 years, were evaluated on two occasions, separated by 3 to 5 days. An IMU and a Cervical Range of Motion device (CROM) were used to assess craniocervical ROM in the three spatial planes. Validity was assessed by comparing IMU and CROM data using the Pearson correlation coefficient, the paired t-test and Bland–Altman plots. Intra-day and inter-day relative reliability were determined using the Intraclass Correlation Coefficient (ICC). The Standard Error of Measurement (SEM) and the Minimum Detectable Change at a 90% confidence level (MDC90) were obtained for absolute reliability. Results: High correlations were detected between methods in both groups on the sagittal and frontal planes (r > 0.9), although this was reduced in the case of the transverse plane. Bland–Altman plots indicated bias below 5º, although for the range of cervical rotation in the CP group, this was 8.2º. The distance between the limits of agreement was over 23.5º in both groups, except for the range of flexion-extension in the control group. ICCs were higher than 0.8 for both comparisons and groups, except for inter-day comparisons of rotational range in the CP group. Absolute reliability showed high variability, with most SEM below 8.5º, although with worse inter-day results, mainly in CP subjects, with the MDC90 of rotational range achieving more than 20º. Conclusions: IMU application is highly correlated with CROM for the assessment of craniocervical movement in CP and healthy subjects; however, both methods are not interchangeable. The IMU error of measurement can be considered clinically acceptable; however, caution should be taken when this is used as a reference measure for interventions.
Background: Axial spondyloarthritis (axSpA) affects spinal muscles, due to inflammation and structural damage. The mechanical properties of the muscles, such as tone or stiffness, could be altered in axSpA. The aim of this work is to analyze the mechanical properties of cervical and lumbar spine muscles in axSpA patients and their relationship with metrology measures, function, disease activity, structural damage and quality of life. Methods: axSpA patients and age/gender/BMI matched healthy controls were recruited. The muscle mechanical properties (MMPs), such as tone or frequency, stiffness, decrement (linear elastic properties), relaxation and creep (viscoelastic properties), of cervical (semispinalis capitis) and lumbar (erector spinae) muscles were bilaterally measured at rest using myotonometry. Additionally, conventional metrology, BASMI (metrology index), BASDAI (disease activity index), mSASSS (radiological structural damage index) and SF-12 (health-related quality of life questionnaire) were used in the axSpA group. Between-groups comparison, intra-group correlations and multivariable regression analyses were performed to achieve the study aims. Results: Thirty-four axSpA patients (mean age: 46.21 ± 8.53 y) and 34 healthy volunteers (mean age: 43.97 ± 8.49 y) were recruited. Both in cervical and lumbar spine, linear elastic parameters were significantly higher in axSpA patients in comparison with controls, while viscoelastic parameters were significantly lower. Lumbar muscle frequency, stiffness, relaxation, creep and cervical muscle elasticity were fair to strongly correlated (|0.346|<r<|0.774|) with age, functional status, activity of disease, structural damage and quality of life in axSpA patients. Furthermore, moderate to good fitted multivariate models (0.328<R2<0.697) were obtained combining age, conventional metrology, activity of the disease and function for the estimation of cervical and lumbar MMPs. Conclusion: Mechanical properties of spinal muscles of axSpA patients differ from controls. Lumbar and cervical muscles exhibit greater linear elastic properties and lower viscoelastic properties, which are related with age, clinical and psychophysiological features of axSpA.
This research aimed to identify changes in muscle mechanical properties (MMPs) when a standardized sequence of movements is performed and to determine the influence of acute low back pain (LBP) and age on the MMPs. Socio-demographic, clinical variables and MMPs were collected in 33 patients with LBP and 33 healthy controls. A 2 × 2 × 2 (group × age × time) analysis of variance (ANOVA) mixed model was used to determine the effect of the study factors on the different MMPs. There were no significant triple interactions. After the movements, tone and stiffness increased 0.37 Hz and 22.75 N/m, respectively, in subjects <35 years, independent of their clinical status. Relaxation showed differences by age in healthy subjects and creep in LBP subjects. Furthermore, elasticity was higher in <35 years (p < 0.001) without the influence of any other factor. In conclusion, sequenced movements can modify tone and stiffness as a function of age, while age-associated changes in viscoelastic characteristics depends on pain but not on movements. The MMPs should be assessed, not only at the beginning of the physical examination at rest, but also along the patient’s follow-up, depending on their pain and age, in a clinical setting.
An analysis of the muscle mechanical properties (MMPs) of the pelvic floor muscles (PFMs) is relevant for understanding the physiopathology of urinary incontinence (UI). However, there is no objective and reliable methodology currently available for quantifying the MMPs of PFMs. Thus, the objective was to determine the intra-rater and inter-rater reliability of the MMPs of PFM assessment with a hand-held tonometer device, called the MyotonPRO, in young women with and without UI. Sociodemographic and pelvic floor questionnaires, plus MMPs of PFMs were assessed in 38 nulliparous women with UI and 40 matched healthy women by two trained physiotherapists on two different occasions, 48–72 h apart. Good to excellent absolute reliability was found for tone, stiffness, and decrement of both intra- and inter-rater analyses in both study groups (Intraclass Correlation Coefficient ranged from 0.75 to 0.92), with a trend of lower values for relaxation and creep. The standard error of measurement (SEM) did not achieve 10% of the mean values for any MMPs. The minimum detectable change (MDC) values were also provided for clinical applications. In conclusion, the relative reliability of tone, stiffness, and the assessment of the decrement of PFMs with MyotonPRO is good to excellent for UI and healthy women. The SEM and MDC values were acceptable for their application in clinical settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.