Purpose To evaluate the diagnostic accuracy of a commercially available test kit for noninvasive prenatal determination of the fetal RhD status (NIPT-RhD) with a focus on early gestation and multiple pregnancies. Methods The FetoGnost RhD assay (Ingenetix, Vienna, Austria) is routinely applied for clinical decision making either in woman with anti-D alloimmunization or to target the application of routine antenatal anti-D prophylaxis (RAADP) to women with a RhD positive fetus. Based on existing data in the laboratory information system the newborn’s serological RhD status was compared with NIPT RhD results. Results Since 2009 NIPT RhD was performed in 2968 pregnant women between weeks 5 + 6 and 40 + 0 of gestation (median 12 + 6) and conclusive results were obtained in 2888 (97.30%) cases. Diagnostic accuracy was calculated from those 2244 (77.70%) cases with the newborn’s serological RhD status reported. The sensitivity of the FetoGnost RhD assay was 99.93% (95% CI 99.61–99.99%) and the specificity was 99.61% (95% CI 98.86–99.87%). No false-positive or false-negative NIPT RhD result was observed in 203 multiple pregnancies. Conclusion NIPT RhD results are reliable when obtained with FetoGnost RhD assay. Targeted routine anti-D-prophylaxis can start as early as 11 + 0 weeks of gestation in singleton and multiple pregnancies.
Purpose: To evaluate the diagnostic accuracy of a commercially available test kit for noninvasive prenatal determination of the fetal RhD status (NIPT-RhD) with a focus on early gestation and multiple pregnancies. Methods: The FetoGnost RhD assay (Ingenetix, Vienna, Austria) is routinely applied for clinical decision making either in woman with anti-D alloimmunization or in order to target the application of routine antenatal anti-D prophylaxis (RAADP) to women with a RhD positive fetus. Based on existing data in the laboratory information system the newborn’s serological RhD status was compared with NIPT RhD results. Results: Since 2009 NIPT RhD was performed in 2,968 pregnant women between week 5+6 and 40+0 of gestation (median 12+6) and conclusive results were obtained in 2,888 (97.30%) cases. Diagnostic accuracy was calculated from those 2244 (77.70%) cases with the newborn’s serological RhD status reported. The sensitivity of the FetoGnost RhD assay was 99.93% (95% CI 99.61% - 99.99%) and the specificity was 99.61% (95% CI 98.86% - 99.87%). No false positive or false negative NIPT RhD result was observed in 203 multiple pregnancies. Conclusion: NIPT RhD results are reliable when obtained with FetoGnost RhD assay. Targeted routine anti-D-prophylaxis can start as early as 11+0 weeks of gestation in singleton and multiple pregnancies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.