BackgroundCyanoacrylate(CA)-based tissue adhesives, although not widely used, are a feasible option to fix a mesh during abdominal hernia repair, due to its fast action and great bond strength. Their main disadvantage, toxicity, can be mitigated by increasing the length of their alkyl chain. The objective was to assess the in vitro cytotoxicity and in vivo biocompatibility in hernia repair of CAs currently used in clinical practice (Glubran(n-butyl) and Ifabond(n-hexyl)) and a longer-chain CA (OCA(n-octyl)), that has never been used in the medical field.MethodsFormaldehyde release and cytotoxicity of unpolymerized(UCAs) and polymerized CAs(PCAs) were evaluated by macroscopic visual assessment, flow cytometry and Alamar Blue assays. In the preclinical evaluation, partial defects were created in the rabbit abdominal wall and repaired by fixing polypropylene prostheses using the CAs. At 14 days post-surgery, animals were euthanized for morphology, macrophage response and cell damage analyses.ResultsFormaldehyde release was lower as the molecular weight of the monomer increased. The longest side-chain CA(OCA) showed the highest cytotoxicity in the UCA condition. However, after polymerization, was the one that showed better behavior on most occasions. In vivo, all CAs promoted optimal mesh fixation without displacements or detachments. Seroma was evident with the use of Glubran, (four of six animals: 4/6) and Ifabond (2/6), but it was reduced with the use of OCA (1/6). Significantly greater macrophage responses were observed in groups where Glubran and Ifabond were used vs. sutures and OCA. TUNEL-positive cells were significantly higher in the Glubran and OCA groups vs. the suture group.ConclusionsAlthough mild formaldehyde release occurred, OCA was the most cytotoxic during polymerization but the least once cured. The CAs promoted proper mesh fixation and have potential to replace traditional suturing techniques in hernia repair; the CAs exhibited good tissue integration and effective short-term biocompatibility, with the slightest seroma and macrophage response induced by OCA.
IntroductionBiological and synthetic laminar absorbable prostheses are available for the repair of hernia defects in the abdominal wall. They share the important feature of being gradually degraded in the host, resulting in place the formation of a neotissue. This study was designed to assess the host tissue’s incorporation of collagen bioprostheses and a synthetic absorbable prosthesis.MethodsPartial defects were created in the abdominal walls of 72 New Zealand rabbits and repaired using collagen bioprostheses Tutomesh® and Strattice® or a synthetic prosthesis Bio-A®. Specimens were collected for light microscopy, collagens gene and protein expression, macrophage response and biomechanical resistance at 14, 30, 90 and 180 days post-implantation.ResultsTutomesh® and Bio-A® were gradually infiltrated by the host tissue and almost completely degraded by 180 days post-implantation. In contrast, Strattice® exhibited material encapsulation, no prosthetic degradation and low cell infiltration at earlier timepoints, whereas at later study time, collagen deposition could be observed within the mesh. In the short term, Bio-A® exhibited higher level of collagen 1 and 3 mRNA expression compared with the two other biological prostheses, which exhibited two peaks of higher expression at 14 and 90 days. The expression of collagen III was homogeneous throughout the study and collagen I deposition was more evident in Strattice®. Macrophage response decreased over time in biomeshes. However, in the synthetic mesh remained high and homogeneous until 90 days. The biomechanical analysis demonstrated the progressively increasing tensile strength of all biomaterials.ConclusionsThe tissue infiltration of laminar absorbable prostheses is affected by the structure and composition of the mesh. The synthetic prosthesis exhibited a distinct pattern of tissue incorporation and a greater macrophage response than did the biological prostheses. Of all of the laminar, absorbable biomaterials that were tested in this study, Strattice® demonstrated the optimal levels of integration and degradation.
IntroductionComposite biomaterials designed for the repair of abdominal wall defects are composed of a mesh component and a laminar barrier in contact with the visceral peritoneum. This study assesses the behaviour of a new composite mesh by comparing it with two latest-generation composites currently used in clinical practice.MethodsDefects (7x5cm) created in the anterior abdominal wall of New Zealand White rabbits were repaired using a polypropylene mesh and the composites: PhysiomeshTM; VentralightTM and a new composite mesh with a three-dimensional macroporous polyester structure and an oxidized collagen/chitosan barrier. Animals were sacrificed on days 14 and 90 postimplant. Specimens were processed to determine host tissue incorporation, gene/protein expression of neo-collagens (RT-PCR/immunofluorescence), macrophage response (RAM-11-immunolabelling) and biomechanical resistance. On postoperative days 7/14, each animal was examined laparoscopically to quantify adhesions between the visceral peritoneum and implant.ResultsThe new composite mesh showed the lowest incidence of seroma in the short term. At each time point, the mesh surface covered with adhesions was greater in controls than composites. By day 14, the implants were fully infiltrated by a loose connective tissue that became denser over time. At 90 days, the peritoneal mesh surface was lined with a stable mesothelium. The new composite mesh induced more rapid tissue maturation than PhysiomeshTM, giving rise to a neoformed tissue containing more type I collagen. In VentralightTM the macrophage reaction was intense and significantly greater than the other composites at both follow-up times. Tensile strengths were similar for each biomaterial.ConclusionsAll composites showed optimal peritoneal behaviour, inducing good peritoneal regeneration and scarce postoperative adhesion formation. A greater foreign body reaction was observed for VentralightTM. All composites induced good collagen deposition accompanied by optimal tensile strength. The three-dimensional macroporous structure of the new composite mesh may promote rapid tissue regeneration within the mesh.
BackgroundMidline laparotomy closure carries a significant risk of incisional hernia. This study examines the behavior of two new suture materials, an elastic material, polyurethane (PUe), and a barbed polydioxanone (PDXb) suture thread in a rabbit model of midline incision closure.MethodsThree 2-cm midline incisions were made in 68 New Zealand White rabbits. The incisions were closed by running suture using four 3/0 threads: polypropylene (PP) (Surgipro®, Covidien), PUe (Assuplus®, Assut Europe), PDX (Assufil®, Assut Europe) or PDXb (Filbloc®, Assut Europe). Animals in each suture group were euthanized 3 weeks and 6 months after surgery. Histological sections of the tissue-embedded sutures were subjected to morphological, collagen expression, macrophage response and uniaxial tensiometry studies.ResultsNo signs of wound dehiscence or complications were observed. At 3 weeks, all sutures were surrounded by connective tissue composed mainly of collagen III. PUe showed greater collagen I expression than the other sutures. All sutures elicited a macrophage response that diminished from 3 weeks to 6 months (p < 0.001). This response was similar for the non-reabsorbable sutures (PP and PUe) yet PDXb showed a significantly greater response than the other reabsorbable suture (PDX) at 3 weeks (p < 0.01). At this early time point, the tensile strength of PUe was similar to that of control intact tissue (p > 0.05).ConclusionThree weeks after surgery, PUe revealed more collagen I deposition than the remaining materials and this translated to a similar biomechanical behavior to linea alba, that could avoid the appearance of short term dehiscences and thus reduce the incidence of incisional hernia. PDXb provides no additional advantages in their behavior regarding PDX suture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.