BackgroundIn laparoscopic surgical procedures, many clinicians recommend supraglottic airway devices as good alternatives to intubation. We compared the i-gel® (i-gel) and LMA Supreme® (Supreme Laryngeal Mask Airway, SLMA) airway devices during laparoscopic cholecystectomy regarding sealing pressure and respiratory parameters before, during, and after pneumoperitoneum.MethodsFollowing Institutional Review Board approval and written informed consent, 93 patients were randomly allocated into the i-gel (n = 47) or SLMA group (n = 46). Insertion time, number of insertion attempts, and fiberoptic view of glottis were recorded. Oropharyngeal leak pressure (OLP), the use of airway manipulation, peak inspiratory pressure, lung compliance, and hemodynamic parameters were measured before, during, and after pneumoperitoneum.ResultsThere were no significant differences between the two groups regarding demographic data, insertion time, fiberoptic view of glottis, and the use of airway manipulation. The gastric tube insertion time was longer in the i-gel group (20.4 ± 3.9 s) than in the SLMA group (16.7 ± 1.6 s) (P < 0.001). All devices were inserted on the first attempt, excluding one case in each group. Peak inspiratory pressure, lung compliance, and OLP changed following carbon dioxide pneumoperitoneum in each group, but there were no significant differences between the groups.ConclusionsBoth the i-gel and SLMA airway devices can be comparably used in patients who undergo laparoscopic cholecystectomy, and they offer similar performance including OLP.
BackgroundBoth the i-gel™ (i-gel) and LMA Supreme™ (Supreme) are new single-use second generation supraglottic airway devices available in pediatric sizes. This study was designed to investigate the i-gel in comparison with the Supreme in children undergoing general anesthesia.MethodsOne hundred children with American Society of Anesthesiologists physical status I or II undergoing general anesthesia were randomly assigned to either the i-gel or the Supreme group (50 children in each group). The device size was chosen according to weight of the children. We assessed the insertion success rate, insertion time, oropharyngeal leak pressure, grade of the fiberoptic glottic view, number of airway manipulations required, and postoperative complications.Results There were no differences in the demographic data between the two groups. The success rate of insertion was same in both groups. The insertion time of the i-gel was longer than that of Supreme (P = 0.004). The oropharyngeal leak pressure in the i-gel group was higher than that in the Supreme group (P = 0.013). On fiberoptic examination, the vocal cords were visible in 90% of the children in the i-gel group and in 96% of the children in the Supreme group. The number of airway manipulations required was higher in the i-gel group (14 cases) than in the Supreme group (1 case) (P < 0.001). There were no differences in complications including blood staining of the device and sore throat between both groups.ConclusionsBoth the i-gel and Supreme provided a satisfactory airway during general anesthesia in children. Compared to the Supreme, the i-gel demonstrated a higher oropharyngeal leak pressure, longer time for insertion, and a greater number of airway manipulations during anesthesia.
The supraglottic airway device (SAD) is an appropriate alternative to tracheal intubation because of its advantages such as stable hemodynamics and decreased airway morbidity. It also helps to maintain adequate ventilation in laparoscopic surgery, with increased peak airway pressure (PAP) under general anesthesia [1,2]. The i-gel Ⓡ (Intersurgical Ltd., UK) is widely used for laparoscopic surgeries [1,3-5]. However, the Baska Mask Ⓡ (Logikal Health Products PTY Ltd., Australia), first introduced in 2012, provides more efficient ventilation by automatically inflating the cuff during positive pressure ventilation. The cuff differs from other non-inflatable cuffs in that it is continuous with the cen-Clinical Research Article Background: The supraglottic airway device is an appropriate alternative to tracheal intubation in laparoscopic surgery. We compared the Baska Mask Ⓡ with i-gel Ⓡ by measuring the oropharyngeal leak pressure (OLP) and hemodynamic and respiratory parameters during laparoscopic cholecystectomy. Methods: A total of 97 patients were randomly allocated to either i-gel group (n = 49) or Baska Mask group (n = 48). Insertion time, number of insertion attempts, fiber-optic view of the glottis, and OLP were recorded. Heart rate, mean arterial pressure, peak airway pressure (PAP), lung compliance, and perioperative complications were assessed before, during, and after pneumoperitoneum. Results: There were no significant differences between the two groups regarding demographic data, insertion time, fiber-optic view of the glottis, and the use of airway manipulation. The OLP was higher in the Baska Mask group than in the i-gel group (29.6 ± 6.8 cmH 2 O and 26.7 ± 4.5 cmH 2 O, respectively; P = 0.014). Heart rate, mean arterial pressure, PAP, and lung compliance were not significantly different between the groups. The incidence of perioperative complications was small and not statistically significant. Conclusions: Both the i-gel and Baska Mask provided a satisfactory airway during laparoscopic cholecystectomy. Compared with the i-gel, the Baska Mask demonstrated a higher OLP.
BackgroundThis study aimed to retrospectively evaluate the use of sugammadex in patients undergoing video-assisted thoracoscopic surgery (VATS) lobectomy.MethodsData were obtained from medical record review of patients who underwent VATS lobectomy from January 2013 to November 2014. Fifty patients were divided into two groups: the sugammadex group (group S, n = 19) was administered sugammadex 2 mg/kg, while the pyridostigmine group (group P, n = 31) received pyridostigmine 20 mg with glycopyrrolate 0.2 mg or atropine 0.5 mg. The primary endpoint measure was the overall incidence of postoperative pulmonary complications including prolonged air leak, pneumonia, and atelectasis. The secondary endpoint measures were the length of postoperative hospital stay and duration of chest tube insertion.ResultsThe overall incidence of postoperative pulmonary complications in patients in group S was significantly lower compared with that of group P (5 [26.3%] vs. 17 [54.8%]; P = 0.049). Also, the durations of chest tube insertion (5.0 [4.0–7.0] vs. 7.0 [6.0–8.0] days; P = 0.014) and postoperative hospital stay (8.0 [8.0–10.0] vs. 10.0 [9.0–11.0] days; P = 0.019) were shorter in group S compared with group P. Administration of sugammadex was associated reduced with postoperative pulmonary complications (OR: 0.22; 95% CI: 0.05–0.87; P = 0.031).ConclusionsThe use of sugammadex, compared with pyridostigmine, showed a significantly reduced overall incidence of postoperative pulmonary complications and decreased duration of chest tube use and postoperative hospital stay in patients undergoing VATS lobectomy, suggesting that sugammadex might be helpful in improving clinical outcomes in such patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers