Integrating fluid transport systems on a single chip with micro-scale detectors has significant advantages, including increased resolution, faster response, smaller sample sizes, and increased parallelism of analysis. To realize the detection of low concentration bioparticles, conventional techniques involve sample culturing to increase particle count to a critical mass at the detection sites, which is time-consuming and often unfeasible under field conditions. By attracting target cells from the bulk onto the sensing electrodes to enrich local cell count in real time, sensitivity can be increased by orders of magnitude. Directed line formation of particles on designated electrodes can be realized by our new asymmetric polarization AC electro-osmotic (ACEO) mechanism based on electrochemical reaction, which shows better particle trapping than that of conventional ACEO. This paper also presents a cantilever ACEO particle trap.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.