Background: Surgical Chest drain insertion is a lifesaving procedure. It requires skills and experience towards its prompt insertion. Quite often there is delay or failure caused in its insertion due to excessive fat and loose skin in the axillary area while using the conventional methods. Numerous guidelines exist advising its safe placement, but mishaps still occur, as reported multiple times, while placing the chest drain. In addition to this, a delay or failure of its successful insertion can lead to disastrous consequences. Case: We would like to share, with fellow readers, a novel technique which we used in placing a surgical chest drain successfully. We used a gum bougie to guide the chest drain into the pleural cavity instead of using metal trocar, stellate or long forceps. Conclusion: By using this method, we experienced that not only it reduced the amount of time taken for the procedure, but it also had positive impact on the ease of insertion without fear of causing damage to internal organs, which ultimately boosted the operator's confidence.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.