A rapid, robust and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for bioanalysis of TJ0711, a novel vasodilatory β-blocker in dog plasma. This assay is able to chromatographically separate TJ0711 from its isobaric metabolite as well as glucuronide conjugates. Chromatographic separation was achieved on a Welch Ultimate-XB C column (2.1 × 100 mm, 3 μm). The analyte and internal standard (propranolol) were extracted from plasma by liquid-liquid extraction using ethyl acetate. The mass spectrometric detection was carried out in positive ion multiple reaction monitoring mode. Good linearity was obtained over the concentration range of 0.5-500 ng/mL (r > 0.99) for TJ0711. Moreover, the method had good accuracy (RE ranging from -2.70 to -0.32%) and precision (RSD < 7.55%). TJ0711 was stable in dog plasma for at least 6 h at ambient temperature, for at least 30 days at -20°C and after three freeze-thaw cycles. This method was successfully applied to a preclinical pharmacokinetic study and the results demonstrated linear pharmacokinetics of TJ0711 over a dose range from 0.03 to 0.3 mg/kg. No significant gender differences were observed in TJ0711 plasma pharmacokinetic parameters.
Enantioselective biodistribution studies of 1-[4-(2-methoxyethyl)phenoxy]-3-[2-(2-methoxyphenoxy)ethylamino]-2-propanol hydrochloride (TJ0711), a novel antihypertensive agent, require the accurate and precise quantification of each TJ0711 enantiomer in biological fluids and tissues. Here we report a simple and sensitive liquid chromatography with tandem mass spectrometry method for simultaneous determination of (R)-TJ0711 and (S)-TJ0711 in rat plasma and tissue samples using protein precipitation. The influence of column type, temperature, mobile phase composition, and flow rate on the retention and enantioselectivity was evaluated. The separation of the TJ0711 enantiomers was ultimately achieved on a SUMICHIRAL OA-2500 column in 15 min using isocratic elution with ethanol/hexane (40:60) at a flow rate of 0.8 mL/min. Good linearities of spiked analyte concentration from 5 to 2000 ng/mL were achieved and the correlation coefficients (R) were greater than 0.99. The intra- and inter-day accuracy and precision for both analytes were <15% at all concentration levels, and the extraction recoveries were consistent among the five quality control concentrations. This assay was successfully applied to quantify plasma and tissue concentrations of TJ0711 enantiomers in a preclinical study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.