Introduction PTS (pneumatic transport system) is extensively being used in modern hospitals for rapid transportation of blood samples and other specimens. However, it has a potential impact on blood components, which should be investigated and nullified accordingly. This study was part of a correction program aimed at reducing hemolysis. It was done by comparing paired samples transported manually and by PTS. Materials and Methods This study was initiated to monitor the impact of PTS on hemolysis of clinical biochemistry blood samples. It was performed in two phases—before and after the corrective action taken. Phase I: done after PTS installation but before the corrective action was taken. Duplicate samples from 100 healthy individuals were collected, one set transported by PTS and the other by human carriers. Both sets were assessed for 25 biochemistry analytes, hemolysis index (HI), and acceleration profiles using a data logger. Corrective measures were then taken, followed by phase II of the study. In phase II, the sample size and study design remained the same as phase I. All the test results of PTS and hand-carried samples were statistically analyzed for any significant difference. Result In phase I, all the hemolysis-manifesting parameters, LDH (lactate dehydrogenase), potassium, AST (aspartate transaminase), and phosphorus, were raised in PTS samples as compared with the manual samples. Their differences were significant as the p-values were 0.001, 0.000, 0.025, and 0.047, respectively. The differences for LDH and potassium were clinically significant as well. HI (9%) and peak acceleration (15.7 g) were high in PTS samples.In phase II, no statistically significant difference between paired samples was found for all biochemistry parameters except for a few which were clinically nonsignificant. For PTS samples, HI was 2.5% and the peak acceleration was 11.2 g, whereas for manual samples, HI was 2%. Conclusion Evidence of hemolysis was found in PTS samples as compared with handheld samples, which was resolved after several corrective actions were taken. Thereafter, PTS became reliable for sample delivery in a routine biochemistry laboratory. Hence, each hospital should scrutinize their PTS for its effects on sample integrity to get rid of PTS-induced preanalytical errors.
Introduction: Single-nucleotide polymorphism (SNP) is a single-nucleotide change in a deoxyribose nucleic acid (DNA) sequence that occurs in >1% of population. Methylene tetra hydro folate reductase (MTHFR) C677T (rs1801133) and methionine synthase enzyme (MTR) A2756G (rs1805087) are two such SNPs occurring in coding sequence of the respective genes, which are frequently seen with neural tube defects (NTDs). MTHFR and MTR genes are involved in folate metabolism. The folate level in the course of pregnancy is treated as vital in the etiopathogenesis of NTDs. This study aims to explore the association of SNPs of both genes and red blood cell (RBC) folate levels in the predisposition to NTDs. Aims and Objective: The purpose of this investigation was to determine the relationship of NTDs with polymorphisms in MTHFR and MTR genotype and to estimate and compare the RBC folate levels in NTD patients and controls. Materials and Methods: A total of 397 individuals were enrolled (163 patients and 234 controls) for this observational study. Genotyping to find out MTHFR C677T and MTR A2756G was performed by polymerase chain reaction–restriction fragment length polymorphism technique from DNA extracted from the subject's blood. RBC folate level was estimated by chemiluminescence immunoassay method with the same blood sample. Results: The total RBC folate levels were significantly less among cases compared to controls ( P = 0.020). A significant difference for RBC folate was observed between case and control groups of various genotypes of MTHFR C677T, except heterozygote CT ( P = 0.459). Among MTR A2756G, genotypes with only homozygous AA have significant difference ( P = 0.003) for RBC folate levels. Among different types of NTDs, there were no significant differences for RBC folate levels. Among MTHFR C677T, T allele possessed 1.9 times risk compared to C allele for the occurrence of NTDs. In MTR A2756G polymorphism, the odds of developing NTDs were 1.6 times in heterozygous AG compared to homozygous AA. Similarly, the risk for NTDs was three times higher in subjects with both heterozygous AG and CT genotypes compared to wild-type homozygous AA and CC genotypes. Conclusion: The total RBC folate levels were significantly less among cases compared to controls, and the genotypes had no such effect in decrease in RBC folate levels. The presence of mutant allele in homozygous or heterozygous condition for both SNPs had increased risk associated with NTDs.
The present article illustrates an attempt to design and test the reproducibility of low-cost patient positioning devices prepared in-house in the radiotherapy department. A rigid wood-polymer composite material stands with angulations, scales, and support was designed as a new method for immobilization of the mobile target using a thermoplastic mask and a carbon fiber base plate. The lower mobile target, i.e., the penis of a patient, was immobilized by this method. A computed tomography simulation was performed for the patient. This device fit was suitable, comfortable, and had good reproducibility and repeatability, which was proven in daily radiotherapy. Reproducibility and accuracy were tested by serial electronic portal imaging detectors. The positioning devices showed variations within 2–3 mm on consecutive treatment days which were within acceptable limits. It is therefore concluded that low-cost patient positioning devices for the mobile target can be fabricated from available materials in-house. With the help of these in-house available materials, we can also fabricate other types of immobilization devices for particular techniques. It is considerably cheaper than commercially available products.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.