ObjectivesThe purpose of this study was to validate a patch-based image denoising method for ultra-low-dose CT images. Neural network with convolutional auto-encoder and pairs of standard-dose CT and ultra-low-dose CT image patches were used for image denoising. The performance of the proposed method was measured by using a chest phantom.Materials and methodsStandard-dose and ultra-low-dose CT images of the chest phantom were acquired. The tube currents for standard-dose and ultra-low-dose CT were 300 and 10 mA, respectively. Ultra-low-dose CT images were denoised with our proposed method using neural network, large-scale nonlocal mean, and block-matching and 3D filtering. Five radiologists and three technologists assessed the denoised ultra-low-dose CT images visually and recorded their subjective impressions of streak artifacts, noise other than streak artifacts, visualization of pulmonary vessels, and overall image quality.ResultsFor the streak artifacts, noise other than streak artifacts, and visualization of pulmonary vessels, the results of our proposed method were statistically better than those of block-matching and 3D filtering (p-values < 0.05). On the other hand, the difference in the overall image quality between our proposed method and block-matching and 3D filtering was not statistically significant (p-value = 0.07272). The p-values obtained between our proposed method and large-scale nonlocal mean were all less than 0.05.ConclusionNeural network with convolutional auto-encoder could be trained using pairs of standard-dose and ultra-low-dose CT image patches. According to the visual assessment by radiologists and technologists, the performance of our proposed method was superior to that of large-scale nonlocal mean and block-matching and 3D filtering.
We present a new LA-ICP-MS system for zircon fission-track (FT) and U-Pb double dating, whereby a femtosecond laser combined with galvanometric optics simultaneously ablates multiple spots to measure average surface U contents. The U contents of zircon measured by LA-ICP-MS and standardized with the NIST SRM610 glass are comparable to those measured by the induced FT method, and have smaller analytical errors. LA-ICP-MS FT dating of seven zircon samples including three IUGS age standards is as accurate as the external detector method, but can give a higherprecision age depending on the counting statistics of the U content measurement. Double dating of the IUGS age standards gives FT and U-Pb ages that are in agreement. A chip of the Nancy 91500 zircon has a homogeneous U content of 84 ppm, suggesting the possibility of using this zircon as a matrix-matched U-standard for FT dating. When using the Nancy 91500 zircon as a U-standard, a zeta calibration value of 42-43 year cm 2 for LA-ICP-MS FT dating is obtained. While this value is strictly valid only for the particular session, it can serve as a reference for other studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.