Introduction: Current echocardiographic parameters have a limitation in assessing mitral valve (MV) apparatus in rheumatic mitral stenosis (MS) patient. In the current study, we use 2 dimensional (2D) longitudinal strain (S) and strain rate (Sr) imaging in evaluating the papillary muscle longitudinal strain (LS) as an objective and quantitative echocardiographic parameter with high reproducibility in the assessment of MV apparatus in patients with mild to moderate rheumatic MS with preserved ejection fraction (EF%). Patients and Method: The study included 40 patients with established diagnosis of MS subdivided in to 31 patients with moderate MS (mean age: 32 ± 5) and 9 patients with mild MS (mean age: 31 ± 6). 20 healthy individuals (mean age 31 ± 6) as a control for cases. The mitral valve area (MVA) was estimated using planimetry and pressure half time (PHT) methods. 2D longitudinal systolic S and Sr imaging was carried out for all participants from the apical long axis (LAX), 4 chamber (4C), 2 chamber (2C) views. Global longitudinal systolic S and Sr were estimated by averaging the 3 apical views. Longitudinal myocardial strain of papillary muscle PMs was assessed by the use of the free strain method from apical 4 chamber view for the antrolateral papillary muscle (APM) and apical long axis view for postromedial papillary muscle (PPM). Results: Patients with MS had significantly decreased longitudinal LV systolic S and Sr in comparison with control group (p < 0.001) despite no significant differences in LV EF%, LVESD and LVEDD were determined between the 3 groups. APM-LS and PPM-LS had significantly decreased values in patient with MS in comparison with control group (p < 0.001). Conclusion: Patients with MS and preserved EF% had decreased APM-LS & PPM-LS in comparison with control group, and had decreased longitudinal LV systolic S and Sr when compared with control group. 2D strain as well as Sr imaging might be a useful method for assessment of mitral valve apparatus in patients with MS & preserved EF%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.