Self-perceived lactose-intolerant respondents had a significantly lower calcium intake from dairy foods and reported having a significantly higher rate of physician-diagnosed diabetes and hypertension.
BackgroundLiterature has identified detrimental health effects from the indiscriminate use of artificial nighttime light. We examined the co-distribution of light at night (LAN) and breast cancer (BC) incidence in Georgia, with the goal to contribute to the accumulating evidence that exposure to LAN increases risk of BC.MethodsUsing Georgia Comprehensive Cancer Registry data (2000–2007), we conducted a case-referent study among 34,053 BC cases and 14,458 lung cancer referents. Individuals with lung cancer were used as referents to control for other cancer risk factors that may be associated with elevated LAN, such as air pollution, and since this cancer type was not previously associated with LAN or circadian rhythm disruption. DMSP-OLS Nighttime Light Time Series satellite images (1992–2007) were used to estimate LAN levels; low (0–20 watts per sterradian cm2), medium (21–41 watts per sterradian cm2), high (>41 watts per sterradian cm2). LAN levels were extracted for each year of exposure prior to case/referent diagnosis in ArcGIS.ResultsOdds ratios (OR) and 95% confidence intervals (CI) were estimated using logistic regression models controlling for individual-level year of diagnosis, race, age at diagnosis, tumor grade, stage; and population-level determinants including metropolitan statistical area (MSA) status, births per 1,000 women aged 15–50, percentage of female smokers, MSA population mobility, and percentage of population over 16 in the labor force. We found that overall BC incidence was associated with high LAN exposure (OR = 1.12, 95% CI [1.04, 1.20]). When stratified by race, LAN exposure was associated with increased BC risk among whites (OR = 1.13, 95% CI [1.05, 1.22]), but not among blacks (OR = 1.02, 95% CI [0.82, 1.28]).ConclusionsOur results suggest positive associations between LAN and BC incidence, especially among whites. The consistency of our findings with previous studies suggests that there could be fundamental biological links between exposure to artificial LAN and increased BC incidence, although additional research using exposure metrics at the individual level is required to confirm or refute these findings.
Circadian disruption has been linked with inflammation, an established cancer risk factor. Per3 clock gene polymorphisms have also been associated with circadian disruption and with increased cancer risk. Patients completed a questionnaire and provided a blood sample prior to undergoing a colonoscopy (n = 70). Adjusted mean serum cytokine concentrations (IL-6, TNF-alpha, gamma-INF, IL-1ra, IL-1-beta, VEGF) were compared among patients with high and low scores for fatigue (Multidimensional Fatigue Inventory), depressive symptoms (Beck Depression Inventory II), or sleep disruption (Pittsburgh Sleep Quality Index), or among patients with different Per3 clock gene variants. Poor sleep was associated with elevated VEGF, and fatigue-related reduced activity was associated with elevated TNF-alpha concentrations. Participants with the 4/5 or 5/5 Per3 variable tandem repeat sequence had elevated IL-6 concentrations compared to those with the 4/4 genotype. Biological processes linking circadian disruption with cancer remain to be elucidated. Increased inflammatory cytokine secretion may play a role.
The adverse respiratory effects of agricultural dust inhalation are mediated in part by endotoxin, a constituent of gram-negative bacterial cell walls. This study quantified personal work-shift exposures to inhalable dust, endotoxin, and its reactive 3-hydroxy fatty acid (3-OHFA) constituents among workers in grain elevators, cattle feedlots, dairies, and on corn farms. Exposures were compared with post-work-shift nasal lavage fluid inflammation markers and respiratory symptoms. Breathing-zone personal air monitoring was performed over one work shift to quantify inhalable dust (Institute of Medicine samplers), endotoxin (recombinant factor C [rFC] assay), and 3-OHFA (gas chromatography/mass spectrometry). Post-shift nasal lavage fluids were assayed for polymorphonuclear neutrophils (PMN), myeloperoxidase (MPO), interleukin 8 (IL-8), albumin, and eosinophilic cation protein (ECP) concentrations. The geometric mean (GSD) of endotoxin exposure (rFC assay) among the 125 male participants was 888 +/- (6.5) EU/m(3), and 93% exceeded the proposed exposure limit (50 EU/m(3)). Mean PMN, MPO, albumin, and ECP levels were two- to threefold higher among workers in the upper quartile of 3-OHFA exposure compared to the lowest exposure quartile. Even numbered 3-OHFA were most strongly associated with nasal inflammation. Symptom prevalence was not elevated among exposed workers, possibly due to endotoxin tolerance or a healthy worker effect in this population. This is the first study to evaluate the relationship between endotoxin's 3-OHFA constituents in agricultural dust and nasal airway inflammation. More research is needed to characterize the extent to which these agents contribute to respiratory disease among agricultural workers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.