Background Prior research has provided inconsistent data regarding the risk factors associated with complications from arterial cannulation. The goal of this study was to clearly define the incidence and risks factors associated with arterial cannulation complications. Methods After obtaining institutional review board approval, all patients requiring arterial line placement with documentation were included in this retrospective study between January 1, 2006, and December 31, 2012. Leveraging two robust data warehouses, the Perioperative DataMart and the Mayo Clinic Life Silences System, the authors cross-matched arterial line cannulation with a documented vascular consult, neurologic consult, infection, or return to surgery within 30 days in order to identify the initial patient population. Results A total of 62,626 arterial lines were placed in 57,787 patients, and 90.1% of the catheters placed were 20-gauge catheters. The radial artery was cannulated in 94.5% of patients. A total of 21 patients were identified as having experienced vascular complications or nerve injuries, resulting in a complication rate of 3.4 per 10,000 (95% CI, 2.1 to 5.1). Cardiac surgery had the largest number of catheters placed (n = 15,419) with 12 complications (complication rate = 7.8 per 10,000; 95% CI, 4.0 to 13.6). The rate of complications differed significantly (P < 0.001) across the three most common catheter sizes (2.7 per 10,000 [95% CI, 1.5 to 4.4] for 20 gauge, 17.2 per 10,000 [95% CI, 4.7 to 43.9] for 18 gauge, and 9.4 per 10,000 [95% CI, 1.1 to 34.1] for 5 French). Conclusion In a large retrospective study, the authors document a very low rate of complications with arterial line placement.
While the world awaits a widely available COVID-19 vaccine, availability of testing is limited in many regions and can be further compounded by shortages of reagents, prolonged processing time and delayed results. One approach to rapid testing is to leverage the volatile organic compound (VOC) signature of SARS-CoV-2 infection. Detection dogs, a biological sensor of VOCs, were utilized to investigate whether SARS-CoV-2 positive urine and saliva patient samples had a unique odor signature. The virus was inactivated in all training samples with either detergent or heat treatment. Using detergent-inactivated urine samples, dogs were initially trained to find samples collected from hospitalized patients confirmed with SARS-CoV-2 infection, while ignoring samples collected from controls. Dogs were then tested on their ability to spontaneously recognize heat-treated urine samples as well as heat-treated saliva from hospitalized SARS-CoV-2 positive patients. Dogs successfully discriminated between infected and uninfected urine samples, regardless of the inactivation protocol, as well as heat-treated saliva samples. Generalization to novel samples was limited, particularly after intensive training with a restricted sample set. A unique odor associated with SARS-CoV-2 infection present in human urine as well as saliva, provides impetus for the development of odor-based screening, either by electronic, chemical, or biological sensing methods. The use of dogs for screening in an operational setting will require training with a large number of novel SARS-CoV-2 positive and confirmed negative samples.
BackgroundAtrial fibrillation (AF) affects around 2% of the population and early detection is beneficial, allowing patients to begin potentially life-saving anticoagulant therapies. Blood pressure (BP) monitors may offer an opportunity to screen for AF.AimTo identify and appraise studies which report the diagnostic accuracy of automated BP monitors used for opportunistic AF detection.MethodsA systematic search was performed of the MEDLINE, MEDLINE In-Process and EMBASE literature databases. Papers were eligible if they described primary studies of the evaluation of a BP device for AF detection, were published in a peer-reviewed journal and reported values for the sensitivity and specificity. Included studies were appraised using the QUADAS-2 tool to assess their risk of bias and applicability to opportunistic AF detection. Values for the sensitivity and specificity of AF detection were extracted from each paper and compared.Results and ConclusionsWe identified seven papers evaluating six devices from two manufacturers. Only one study scored low risk in all of the QUADAS-2 domains. All studies reported specificity >85% and 6 reported sensitivity >90%. The studies showed that BP devices with embedded algorithms for detecting arrhythmias show promise as screening tools for AF, comparing favourably with manual pulse palpation. But the studies used different methodologies and many were subject to potential bias. More studies are needed to more precisely define the sensitivity and specificity of opportunistic screening for AF during BP measurement before its clinical utility in the population of interest can be assessed fully.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.