A retrospective review of admission preductal oxygen saturations of neonates with antenatally diagnosed critical congenital heart disease (CCHD) was performed to investigate the differences in newborn pulse oximetry (Pulsox) by specific CCHD diagnosis. Saturations were recorded at median of < 1 h (range < 1-9 h) after delivery. Data was stratified by CCHD diagnosis and analysed according to the three different admission Pulsox thresholds, ≤ 90, ≤ 92 and ≤ 95%. Of the 276 neonates studied, 208 were clinically well at admission, with no co-morbidities, gestation > 34 weeks and birth weight > 1.8 kg. A statistically significant increase in the proportion with low admission saturations was seen using ≤ 95% saturation threshold (72% (95% CI 66-78)) compared to ≤ 92% (52% (95% CI 46-59)) and ≤ 90% (46% (95% CI 39-52)). Subgroup analysis found the proportion of neonates with low saturations varied according to the specific CCHD diagnosis with only 20-42% of neonates with aortic stenosis, coarctation of the aorta and pulmonary stenosis having saturations ≤ 95%. Conclusion: The proportion of neonates with low admission oxygen saturation varied by CCHD diagnosis with those without critically reduced pulmonary blood flow not having low admission saturations, in general, even using the ≤ 95% threshold which had the highest proportions of abnormal saturations. This data may assist developing Pulsox screening policies. What is Known: • The addition of pulse oximetry (Pulsox) screening to the routine newborn examination increases the sensitivity of CCHD detection. Pulsox screening is also highly specific for CCHD in asymptomatic neonates, with low false-positive rates. • Early diagnosis of CCHD improves patient outcomes in relation to both morbidity and mortality. What is New: • The proportion of affected infants with an abnormal Pulsox result varies by CCHD diagnosis and screening threshold. In our study using the ≤ 95% threshold gave the highest proportion of neonates with abnormal saturations at admission. • In general, Pulsox yield of abnormal results is low for CCHD diagnoses not associated with critically reduced pulmonary blood flow; however, increasing the Pulsox threshold increased the proportion of infants with an abnormal result.
Neonatal hyperbilirubinaemia requiring phototherapy treatment is a common problem impacting the length of hospital stay and rates of hospital readmission. Previous guidelines included guidance for initiating phototherapy treatment but not for discontinuing phototherapy treatment during initial newborn admission.In response to dissatisfaction from trainees, staff and families regarding the variable approach to discontinuing phototherapy among attending nursery providers, we used quality improvement methodologies to increase utilisation of a rebound hyperbilirubinaemia calculator as a more consistent method for guiding the timing of phototherapy discontinuation. The aim was to increase utilisation of the rebound hyperbilirubinaemia calculator for newborns treated with phototherapy in two newborn nurseries to >90% within 2 years.Sequential interventions focused on increasing provider awareness of the rebound hyperbilirubinaemia calculator and making the calculator simple to access and use.At the university medical centre nursery, the use of the calculator increased from 8.7% to 100%, exceeding the project goal. In the community hospital nursery, there was a statistically significant increase in the rate of utilisation from 3.7% to 79.4%, but this fell slightly below the goal of >90%.Electronic Health Record integration, along with education and addition of prompts to providers, increased utilisation of a rebound hyperbilirubinaemia calculator as a consistent approach for guiding decisions about discontinuing phototherapy treatment in newborns.
Administration of the birth dose of hepatitis B vaccine is an important step in reducing perinatally acquired hepatitis B infection, yet the USA is below the Healthy People 2020 goal for rate of administration.In response to updated Advisory Committee on Immunisation Practices recommendations to administer the dose within 24 hours of birth, we used quality improvement methodology to implement changes that would increase the vaccination rates of healthy newborns in our nurseries. The goal was to improve the proportion of infants who receive the hepatitis B vaccine within 24 hours of birth to >90% within a 2-year period, with a secondary goal of increasing vaccination rates prior to discharge from the nursery to >95%.Multiple Plan–Do–Study–Act (PDSA) cycles were performed. Initial cycles focused on increasing nurse and provider awareness of the updated timing recommendations. Later cycles targeted nursing workflow to facilitate timely administration of the vaccine. We implemented changes at our university medical centre and community hospital newborn nurseries.At the university medical centre nursery, both primary and secondary goals were met; the rate of hepatitis B vaccine administration within 24 hours increased from 81.7% to 96.2%, with vaccine administration prior to discharge increasing from 93.4% to 97.9%. In the community hospital nursery, the baseline rate of hepatitis B vaccine administration within 24 hours was 78.1%, and this increased to 85.8% with the interventions, falling short of the target of >90%. Vaccine administration prior to discharge increased from 87.2% to 92.0%, also not meeting the secondary target of 95%.Interventions that facilitated workflow had additional benefit beyond education alone to improve timing and rates of hepatitis B vaccine administration in both a university medical centre and community hospital nursery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.