We examine these recent developments in pump technology and epidural delivery systems and evaluate how these have enhanced the mothers' birthing experiences.
Background and Aims:Epidural morphine after caesarean section may cause moderate to severe pruritus in women. Epidural oxycodone has been shown in non-obstetric trials to reduce pruritus when compared to morphine. We hypothesised that epidural oxycodone may reduce pruritus after caesarean section.Methods:A randomised controlled trial was conducted in pregnant women at term who underwent caesarean section with combined spinal-epidural technique initiated with intrathecal fentanyl 15 μg. Women received either epidural morphine 3 mg or epidural oxycodone 3 mg via the epidural catheter after delivery. The primary outcome was the incidence of pruritus at 24 h after caesarean section. The secondary outcomes were the pruritus scores, treatment for post-operative nausea and vomiting (PONV), pain scores and maternal satisfaction.Results:One hundred women were randomised (group oxycodone O = 50, morphine M = 50). There was no difference between Group O and M in the incidence of pruritus (n [%] 28 [56%] vs. 31 [62%], P = 0.68) and the worst pruritus scores (mean [standard deviation] 2.6 (2.8) vs. 3.3 [3.1], P = 0.23), respectively. Both groups had similar pain scores at rest (2.7 [2.3] vs. 2.0 [2.7], P = 0.16) and sitting up (5.0 [2.3] vs. 4.6 [2.4], P = 0.38) at 24 h. Pruritus scores were lower at 4–8, 8–12 and 12–24 h with oxycodone, but pain scores were higher. Both groups had a similar need for treatment of PONV and maternal satisfaction with analgesia.Conclusion:There was no difference in the incidence of pruritus at 24 h between epidural oxycodone and morphine. However, pruritus scores were lower with oxycodone between 4 and 24 h after surgery with higher pain scores in the same period.
The same dose of hyperbaric bupivacaine 12 mg and morphine 100 μg administered in the sitting position to both PPTL and CS parturients yielded similar maximal sensory blocks, but PPTL exhibited faster block regression and less hypotension/vasopressor requirement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.