In recent years, some streams and fisheries have been experiencing higher surface water temperatures, which negatively impact cold-water trout species. One potential solution is to provide localized refugia of colder water produced via active cooling. The present work focuses on the design and testing of a small-scale prototype heat exchanger, for such a cooling system. An effectiveness-NTU approach was used to model the heat exchanger and guide initial development of the prototypes. Based on the model, a staggered, tube-bundle heat exchanger was used. Various prototypes of the heat exchanger were tested in a 1/10th scaled model of a section of the creek. The prototypes consisted of just the heat exchanger placed directly in the scaled-stream model and of the heat exchanger placed inside an enclosure with an aperture. The results show that, without the enclosure, the average temperature difference is 0.64 °C, with a corresponding heat transfer requirement of 1.63 kW/°C of cooling. However, with an enclosure, the average temperature difference is 1.95 °C, which required 0.59 kW/°C of cooling. Modifications to the enclosure impact the average temperature difference and the temperature distribution within the enclosure, e.g., decrease the standard deviation of the temperature difference. Thus, the results show the need for the use of the enclosure to reduce the power requirement for the refugia, and obtain a desired temperature difference with a relatively low spatial variation in that temperature difference.
In recent years Spring Creek in South Dakota, a popular fishing location, has been experiencing higher surface water temperatures, which negatively impact cold-water trout species. One potential solution is to provide localized refugia of colder water produced via active cooling. The present work focuses on the design and testing of a small-scale prototype heat exchanger, for such a cooling system. Various prototypes of the heat exchanger were tested in a 1/10th-scaled model of a section of the creek. A staggered, tube-bundle heat exchanger was used. The prototypes consisted of just the heat exchanger placed directly in the scaled-stream model and of the heat exchanger placed inside an enclosure with an aperture. The results show that, without the enclosure, the average temperature difference is 0.64 °C, with a corresponding heat transfer requirement of 1.63 kW/°C of cooling. However, with an enclosure, the average temperature difference is 1.95 °C, which required 0.59 kW/°C of cooling. Modifications to the enclosure decrease the average temperature difference but also decrease the standard deviation of the temperature difference. Thus, the cooling effect is more evenly spread throughout the water in the enclosure. This indicates that the enclosure design can be used to balance the requirements of obtaining a desired temperature difference with a relatively low spatial variation in that temperature difference. These results will be used to guide the design of the large-scale heat exchanger prototype.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.