Objective: The primary objectives were: 1) to study the impact of Qd (500 vs 800 ml/min) on the delivered dose by reused dialyzers, and 2) to determine dialysis efficiency of a dialyzer reused 15 times.Materials and Methods: A prospective randomized-controlled crossover study was conducted in 42 thrice-weekly hemodialysis (HD) patients (630 HD sessions in each Qd). Delivered doses at both Qds were assessed by single-pool Kt/V (spKt/V), equilibrated Kt/V (eKt/V) and online clearance monitoring Kt/V (Kt/VOCM), measured at mid-week HD session using a new dialyzer and then again at every mid-week HD session.Results: Although the spKt/V in HD sessions using new dialyzers at Qd of 500 ml/min was slightly lower than spKt/V at Qd of 800 ml/min (2.19±0.08 vs. 2.34±0.08, respectively, P=0.04), when accounting for urea rebound as assessed by eKt/V and Kt/VOCM, there was no significant difference. The average delivered doses in dialyzers reused 15 times, with the mean average of spKt/V, eKt/V and Kt/VOCM at Qd 500 ml/min, were not significantly inferior to the delivered doses at Qd 800 ml/min. Reusing a dialyzer 15 times did not decrease dialysis efficiency and delivered doses in all HD sessions reached spKt/V >1.4.Conclusion: Increasing Qd over 500 ml/min for modern dialyzers does not significantly increase delivered dose of dialysis. Dialyzer reuse does not affect dialysis efficiency and provides adequate dialysis therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.