Altitude exposure is associated with decreased exercise capacity and increased pulmonary vascular resistance (PVR).Echocardiographic measurements of pulmonary haemodynamics and a cardiopulmonary exercise test were performed in 13 healthy subjects at sea level, in normoxia and during acute hypoxic breathing (1 h, 12% oxygen in nitrogen), and in 22 healthy subjects after acclimatisation to an altitude of 5,050 m. The measurements were obtained after randomisation, double-blinded to the intake of placebo or the endothelin A receptor blocker sitaxsentan (100 mg?day -1 for 7 days). Blood and urine were sampled for renal function measurements. Normobaric as well as hypobaric hypoxia increased PVR and decreased maximum workload and oxygen uptake (V9O 2 ,max). Sitaxsentan decreased PVR in acute and chronic hypoxia (both p,0.001), and partly restored V9O 2 ,max, by 30 % in acute hypoxia (p,0.001) and 10% in chronic hypoxia (p,0.05). Sitaxsentan-induced changes in PVR and V9O 2 ,max were correlated (p50.01). Hypoxia decreased glomerular filtration rate and free water clearance, and increased fractional sodium excretion. These indices of renal function were unaffected by sitaxsentan intake.Selective endothelin A receptor blockade with sitaxsentan improves mild pulmonary hypertension and restores exercise capacity without adverse effects on renal function in hypoxic normal subjects.
Among patients with popliteal and infrapopliteal PAD undergoing PVI, DM was associated with higher mortality, major amputations and MAE that was independent of baseline comorbidities. Our data suggested the need for future studies evaluating existing and/or novel therapies to improve the poor long-term outcomes in diabetic patients with popliteal and infrapopliteal PAD.
Background: Debulking and ablative techniques are sometimes used for the treatment of in-stent restenosis (ISR) secondary to resistant stent under-expansion (SU). The safety and effectiveness of orbital atherectomy (OA) in this cohort of patients has not been reported. Methods: We retrospectively evaluated consecutive patients treated with OA for ISR secondary to balloon undilatable SU at two academic tertiary care centers between October 2016 and June 2019. Angiographic or intravascular imaging identified SU. Technical success was defined as residual 0% stenosis with TIMI III flow. Results: A total of 41 patients were included in the study. Patients had an average age of 65 ± 12 years; 73% male, 61% diabetic, 41% with prior coronary artery bypass grafting, 61% with a prior incident of ISR, 51% presented with stable angina, 17% unstable angina, and 32% non-ST elevation myocardial infarction (MI). Implantation of the under-expanded stents occurred between 2 months and 22 years prior to the index procedure. A total of 27% of patients had multiple layers of stents in the target lesion and 32% of patients had in-stent chronic total occlusion. Technical success was achieved in 40 (98%) patients. There were 2 (5%) major adverse cardiovascular events; both of them were periprocedural MI from the no-reflow phenomenon. There were 2 (5%) Ellis type II coronary perforations that required no intervention. Conclusions: OA can be effectively performed as an adjunctive tool in the treatment of ISR with balloon undilatable SU. The use of OA for SU is not approved by the U.S. Food and Drug Administration and is "off label" and caution must be used to limit any device/stent interaction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.