We evaluated the influence on milk production of feeding early lactation cows a diet that included 14.5% crude protein (CP) and that did not meet methionine (Met) requirements or that met them by supplying rumen‐protected Met (RPMet). Thirty‐nine multiparous Holstein cows were allocated into two groups. For 15 weeks after calving, each group was fed one of the two total mixed rations, Control ( n = 20) or Treatment ( n = 19). The Treatment group received added RPMet at 0.034% (8 g/day) of the Control diet on dry matter basis. The adequacies of Met for the Control and Treatment groups were 96% and 106%, respectively, and for other amino acids, >110%. The CP level (14.5%) was 1 percentage point lower than that recommended by the Japanese Feeding Standard (2006). No between‐group differences were found in milk yield (40 kg/day), milk composition, plasma profile, rumen fermentation, nitrogen balance, or cow health. Met intake and the amount of rumen‐undegradable feed Met were higher in the Treatment group ( p < 0.05). Microbial Met and total metabolizable Met did not differ between groups. Supplying RPMet in a 14.5% CP diet during early lactation did not dramatically affect milk production, because the amount of total metabolizable Met was unchanged.
This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.