BackgroundCoronary artery bypass grafting (CABG) on cardiopulmonary bypass (CBP) is associated with significant morbidity and mortality. In high-risk patients, doomed for reoperation the adverse effects of CBP may be more striking. We evaluated the results of reoperative CABG (redo-CABG) by either off-pump (OPCAB) or on-pump (ONCAB). Clinical endpoints were perioperative myocardial infarction, mortality, survival and as the most striking difference between prior studies the quality of life (QoL).MethodsWe performed a prospective, non-randomized assessment for patients who underwent redo-CABG by redo-OPCAB (n = 40) or redo-ONCAB (n = 40) at our institution between January 2007 and December 2010. For evaluation of QoL the SF-36 health survey was used with self-administered assessment.ResultsDuring follow-up 37 of 40 patients were alive in the redo-OPCAB group versus 32 of 40 patients in the redo-ONCAB group (p < 0.05). The shorter operation time, less blood loss, fewer perioperative myocardial infarctions, the higher rate of totally arterial revascularisation and shorter intensive care stay were the significantly beneficial differences for patients in the redo-OPCAB group (p < 0.05). The 3-year survival rate was higher in the redo-OPCAB group with 81 ± 12% versus 63 ± 9%in the redo-ONCAB group. The quality of life survey did not reveal any significant differences between both groups.ConclusionIn conclusion, with our present retrospective study, we could demonstrate the safety and efficacy of the redo-OPCAB technique with even higher 3-year survival rate. Both techniques seem to have similar impact on the outcome of patients.
Based on our experience, we suggest that implantation of a loop recorder represents an additional tool for a selected group of children. Due to its invasive nature, it should be restricted to patients at high risk, or those in which there is substantial clinical suspicion of the likelihood of serious arrhythmias when conventional testing has been inconclusive. In this cohort, implantation of the loop recorder either helps to establish the correct diagnosis, or to exclude an arrhythmic event, thus avoiding unnecessary escalation of therapy and providing reassurance for the family.
Hybrid aortic repair using the FET in acute DeBakey type I aortic dissection does not elevate the perioperative risk of mortality and provides excellent aortic remodelling with low distal re-intervention rate in mid-term follow-up.
Simultaneous application of the David and FET procedure in patients with acute aortic dissection is safe and feasible in experienced hands as compared with standard aortic root replacement plus FET. The mid-term outcomes are encouraging and noninferior to conventional surgery results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.