ATI may be transient and do not always lead to a worse clinical outcome. Sustained high levels of ATI, however, lead to permanent LOR. Patients with low IFX trough levels at week 14 are at risk for ATI formation and IFX discontinuation. Therefore, we recommend to measure IFX trough levels at week 14 and at time of LOR. When undetectable or low, ATI should be determined and if positive followed up on consecutive time points to rule out sustained ATI.
ObjectiveAlthough low infliximab trough concentrations and antibodies to infliximab (ATI) are associated with poor outcomes in patients with Crohn's disease (CD), the clinical relevance of ATI in patients with adequate infliximab concentrations is uncertain. We evaluated this question using an assay sensitive for identification of ATI in the presence of infliximab.DesignIn an observational study, 1487 trough serum samples from 483 patients with CD who participated in four clinical studies of maintenance infliximab therapy were analysed using a fluid phase mobility shift assay. Infliximab and ATI concentrations most discriminant for remission, defined as a C-reactive protein concentration of ≤5 mg/L, were determined by receiver operating characteristic curves. A multivariable regression model evaluated these factors as independent predictors of remission.ResultsBased upon analysis of 1487 samples, 77.1% of patients had detectable and 22.9% had undetectable infliximab concentrations, of which 9.5% and 71.8%, respectively, were positive for ATI. An infliximab concentration of >2.79 μg/mL (area under the curve (AUC)=0.681; 95% CI 0.632 to 0.731) and ATI concentration of <3.15 U/mL (AUC=0.632; 95% CI 0.589 to 0.676) were associated with remission. Multivariable analysis showed that concentrations of both infliximab trough (OR 1.8; 95% CI 1.3 to 2.5; p<0.001) and ATI (OR 0.57; 95% CI 0.39 to 0.81; p=0.002) were independent predictors of remission.ConclusionsThe development of ATI increases the probability of active disease even at low concentrations and in the presence of a therapeutic concentration of drug during infliximab maintenance therapy. Evaluation of strategies to prevent ATI formation, including therapeutic drug monitoring with selective infliximab dose intensification, is needed.
Antibody-based drugs such as infliximab (IFX) are effective for the treatment of inflammatory bowel disease (IBD) and other immune-mediated disorders. The development of antibodies against these drugs may result in unfavorable consequences, including the loss of drug efficacy, hypersensitivity reactions, and other adverse events. Therefore, accurate monitoring of serum drug and anti-drug antibody levels should be an important part of therapy for patients being treated with an antibody-based drug. Current methods for the assessment of anti-drug antibodies and drug levels, involving various bridging ELISA and radioimmunoassay techniques, are limited by their sensitivity, interference, and/or complexity. To overcome these limitations, we have developed a non-radiolabeled homogeneous mobility shift assay (HMSA) to measure the antibodies-to-infliximab (ATI) and IFX levels in serum samples. Full method validation was performed on both the ATI- and IFX-HMSA, and the clinical sample test results were also compared with those obtained from a bridging ELISA method to evaluate the difference in performance between the two assays. Validation of the ATI-HMSA revealed a lower limit of quantitation of 0.012 μg/mL in serum. The linear range of quantitation was 0.029-0.54 μg/mL. The intra- and inter-assay precision was less than 20% of coefficient of variation (CV), and the accuracy (% error) of the assay was less than 20%. In serum samples, ATI as low as 0.036 μg/mL can be measured, even in the presence of 60 μg/mL of IFX in the serum. Sera from 100 healthy subjects were tested to determine the cut point of the assay. ATI-positive samples that had been previously analyzed by using a bridging ELISA from 100 patients were also measured by the new method. There was a high correlation between the two methods for ATI levels (p<0.001). Significantly, the new method identified five false-positive samples from the bridging ELISA method. Validation of the mobility shift IFX assay also showed high assay sensitivity, precision and accuracy. The HMSA method may also be applied to other protein-based drugs to accurately detect serum drug and anti-drug antibody levels.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.