Background:Autoverification is a process of using computer-based rules to verify clinical laboratory test results without manual intervention. To date, there is little published data on the use of autoverification over the course of years in a clinical laboratory. We describe the evolution and application of autoverification in an academic medical center clinical chemistry core laboratory.Subjects and Methods:At the institution of the study, autoverification developed from rudimentary rules in the laboratory information system (LIS) to extensive and sophisticated rules mostly in middleware software. Rules incorporated decisions based on instrument error flags, interference indices, analytical measurement ranges (AMRs), delta checks, dilution protocols, results suggestive of compromised or contaminated specimens, and ‘absurd’ (physiologically improbable) values.Results:The autoverification rate for tests performed in the core clinical chemistry laboratory has increased over the course of 13 years from 40% to the current overall rate of 99.5%. A high percentage of critical values now autoverify. The highest rates of autoverification occurred with the most frequently ordered tests such as the basic metabolic panel (sodium, potassium, chloride, carbon dioxide, creatinine, blood urea nitrogen, calcium, glucose; 99.6%), albumin (99.8%), and alanine aminotransferase (99.7%). The lowest rates of autoverification occurred with some therapeutic drug levels (gentamicin, lithium, and methotrexate) and with serum free light chains (kappa/lambda), mostly due to need for offline dilution and manual filing of results. Rules also caught very rare occurrences such as plasma albumin exceeding total protein (usually indicative of an error such as short sample or bubble that evaded detection) and marked discrepancy between total bilirubin and the spectrophotometric icteric index (usually due to interference of the bilirubin assay by immunoglobulin (Ig) M monoclonal gammopathy).Conclusions:Our results suggest that a high rate of autoverification is possible with modern clinical chemistry analyzers. The ability to autoverify a high percentage of results increases productivity and allows clinical laboratory staff to focus attention on the small number of specimens and results that require manual review and investigation.
Background:Epic Beaker Clinical Pathology (CP) is a relatively new laboratory information system (LIS) operating within the Epic suite of software applications. To date, there have not been any publications describing implementation of Beaker CP. In this report, we describe our experience in implementing Beaker CP version 2012 at a state academic medical center with a go-live of August 2014 and a subsequent upgrade to Beaker version 2014 in May 2015. The implementation of Beaker CP was concurrent with implementations of Epic modules for revenue cycle, patient scheduling, and patient registration.Methods:Our analysis covers approximately 3 years of time (2 years preimplementation of Beaker CP and roughly 1 year after) using data summarized from pre- and post-implementation meetings, debriefings, and the closure document for the project.Results:We summarize positive aspects of, and key factors leading to, a successful implementation of Beaker CP. The early inclusion of subject matter experts in the design and validation of Beaker workflows was very helpful. Since Beaker CP does not directly interface with laboratory instrumentation, the clinical laboratories spent extensive preimplementation effort establishing middleware interfaces. Immediate challenges postimplementation included bar code scanning and nursing adaptation to Beaker CP specimen collection. The most substantial changes in laboratory workflow occurred with microbiology orders. This posed a considerable challenge with microbiology orders from the operating rooms and required intensive interventions in the weeks following go-live. In postimplementation surveys, pathology staff, informatics staff, and end-users expressed satisfaction with the new LIS.Conclusions:Beaker CP can serve as an effective LIS for an academic medical center. Careful planning and preparation aid the transition to this LIS.
ObjectivesThe aims of this study were to identify the causes of severe lipemia in an academic medical center patient population and to determine the relationship between lipemia and hemolysis.Design and methodsRetrospective study was done on the data from the core clinical laboratory at an academic medical center. Lipemic indices were available for all chemistry specimens analyzed over a 16-month period (n=552,029 specimens) and for serum/plasma triglycerides concentrations ordered for clinical purposes over a 16-year period (n=393,085 specimens). Analysis was performed on Roche Diagnostics cobas 8000 analyzers. Extensive chart review was done for all specimens with lipemic index greater than 500 (severely lipemic) and for all specimens with serum/plasma triglycerides greater than 2000 mg/dL. We also determined the relationship between lipemia and hemolysis.ResultsThe most frequent suspected causes of very high lipemic index (>500) were found to be lipid-containing intravenous infusions (54.4% of total; fat emulsions for parenteral nutrition – 47%; propofol −7.4%) and diabetes mellitus (25% of total, mainly type 2). The most frequent suspected causes of very elevated serum/plasma triglycerides (>2000 mg/dL) was diabetes mellitus (64%, mainly type 2) and hyperlipidemia (16.9%). The frequency of hemolysis increased with increasing lipemic index.ConclusionsIntravenous lipid infusions and type 2 diabetes were the most common causes of severe lipemia in this study at an academic medical center. Given that iatrogenic factors are the most common cause of severe lipemia, education and intervention may be helpful in reducing frequency of severe lipemia in patient specimens.
BackgroundHepatitis B virus (HBV) is a common cause of viral hepatitis with significant health complications including cirrhosis and hepatocellular carcinoma. Assays for hepatitis B surface antigen (HBsAg) are the most frequently used tests to detect HBV infection. Vaccination for HBV can produce transiently detectable levels of HBsAg in patients. However, the time course and duration of this effect is unclear. The objective of this retrospective study was to clarify the frequency and duration of transient HBsAg positivity following vaccination against HBV.MethodsThe electronic medical record at an academic tertiary care medical center was searched to identify all orders for HBsAg within a 17 month time period. Detailed chart review was performed to identify all patients who were administered HBV vaccine within 180 days prior to HBsAg testing and also to ascertain likely cause of weakly positive (grayzone) results.ResultsDuring the 17 month study period, 11,719 HBsAg tests were ordered on 9,930 patients. There were 34 tests performed on 34 patients who received HBV vaccine 14 days or less prior to HBsAg testing. Of these 34 patients, 11 had grayzone results for HBsAg that could be attributed to recent vaccination. Ten of the 11 patients were renal dialysis patients who were receiving HBsAg testing as part of routine and ongoing monitoring. Beyond 14 days, there were no reactive or grayzone HBsAg tests that could be attributed to recent HBV vaccination. HBsAg results reached a peak COI two to three days following vaccination before decaying. Further analysis of all the grayzone results within the 17 month study period (43 results out of 11,719 tests) revealed that only 4 of 43 were the result of true HBV infection as verified by confirmatory testing.ConclusionsOur study confirms that transient HBsAg positivity can occur in patients following HBV vaccination. The results suggest this positivity is unlikely to persist beyond 14 days post-vaccination. Our study also demonstrates that weakly positive HBsAg results often do not reflect actual HBV infection, underscoring the importance of confirmatory testing. This study also emphasizes that vaccination-induced HBsAg positives occur most commonly in hemodialysis patients.
Ethylene glycol (EG) is a common cause of toxic ingestions. Gas chromatography (GC)-based laboratory assays are the gold standard for diagnosing EG intoxication. However, GC requires specialized instrumentation and technical expertise that limits feasibility for many clinical laboratories. The objective of this retrospective study was to determine the utility of incorporating a rapid EG assay for management of cases with suspected EG poisoning. The University of Iowa Hospitals and Clinics core clinical laboratory adapted a veterinary EG assay (Catachem, Inc.) for the Roche Diagnostics cobas 8000 c502 analyzer and incorporated this assay in an osmolal gap-based algorithm for potential toxic alcohol/glycol ingestions. The main limitation is that high concentrations of propylene glycol (PG), while readily identifiable by reaction rate kinetics, can interfere with EG measurement. The clinical laboratory had the ability to perform GC for EG and PG, if needed. A total of 222 rapid EG and 24 EG/PG GC analyses were documented in 106 patient encounters. Of ten confirmed EG ingestions, eight cases were managed entirely with the rapid EG assay. PG interference was evident in 25 samples, leading to 8 GC analyses to rule out the presence of EG. Chart review of cases with negative rapid EG assay results showed no evidence of false negatives. The results of this study highlight the use of incorporating a rapid EG assay for the diagnosis and management of suspected EG toxicity by decreasing the reliance on GC. Future improvements would involve rapid EG assays that completely avoid interference by PG.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.