Comparing VDD and DDD pacing, a significantly larger number of VDD-paced patients developed poor atrial signal detection without clinical impact. However, atrial under sensing did not influence the incidence of atrial fibrillation, myocardial infarction, dilated cardiomyopathy, or mortality.
AimAfter pulmonary vein isolation (PVI), dormant conduction (DC) is present in at least one vein in a substantial number of patients. The present study seeks to determine whether there is a relationship between poor contact forces (CF) and the presence of DC after PVI.Methods and resultsThis prospective, operator-blinded, non-randomized dual-centre trial enrolled 34 consecutive patients with paroxysmal atrial fibrillation who were candidates for PVI. Radiofrequency (RF) energy was delivered by using an irrigated-tip force-sensing ablation catheter (Tacticath®, St Jude Medical) at pre-defined target power. The operators were blinded to the CF data at all times. A total of 1476 RF applications were delivered in 743 pre-defined PV segments. For each application, the precise location of the catheter was registered and the following data were extracted from the Tacisys® unit: application duration, minimum contact force, maximum contact force, average contact force (CF), and force–time integral (FTI). Sixty minutes after PVI, spontaneous early recovery (ER) of the left atrium (LA) to PV conduction was evaluated. In the absence of ER, the presence of a DC was evaluated by using intravenous adenosine (ATP). In the 34 patients recruited (23 males; mean age: 62 ± 9 years), all PVs were successfully isolated. At the end of the 60 min waiting period, 22 patients demonstrated at least one spontaneous ER or DC under ATP. The mean CF and FTI per PV segment differed significantly among the different veins but the sites of ER and DC were evenly distributed. However, both the minimum, the first and the mean CF and FTI per PV segment were significantly lower in the PV segments presenting either ER or DC as compared with those without ER or DC (mean CF: 4.9 ± 4.8 vs. 12.2 ± 1.65 g and mean FTI: 297 ± 291 vs. 860 ± 81 g s, P < 0.001 for both). Using multivariate analysis, both the mean CF and the FTI per lesion remained significantly associated with the risk of ER or DC. Moreover, a CF < 5 g per PV segment predicted ER+ and DC+ with a sensitivity of 71% and specificity of 82%. In contrast, ER and DC were very unlikely if RF application was performed with a mean CF > 10 g (negative predictive value: 98.7%).ConclusionBoth a low CF and a low FTI are associated with the ER of the PVI and DC after PVI.
Disclosures: Dr. De Pooter reports speaker fees and honoraria from Medtronic and Biotronik. Dr. Peytchev and dr. Heggermont report that their research institution (CRI Aalst) receives consultancy fees on their behalf from Medtronic, Biotronik, St Jude Medical, Boston Scientific and Microport. Dr Wauters reports speaker and consultancy fees from Biotronik. Dr. le Polain de Waroux reports nonsignificant speaker fees and honoraria for proctoring and teaching activities from Medtronic, Boston Scientific, Abbott and Biotronik. The other authors report no disclosures. Dr. Tung reports speaker and consulting honoraria from Medtronic, Boston Scientific, Abbott, and Biotronik.
Background Conduction disorders requiring permanent pacemaker implantation occur frequently after transcatheter aortic valve replacement (TAVR). This multicenter study explored the feasibility and safety of His bundle pacing (HBP) in TAVR patients with a pacemaker indication to correct a TAVR‐induced left bundle branch block (LBBB). Methods Patients qualifying for a permanent pacemaker implant after TAVR were planned for HBP implant. HBP was performed using the Select Secure (3830; Medtronic) pacing lead, delivered through a fixed curve or deflectable sheath (C315HIS or C304; Medtronic). Successful HBP was defined as selective or nonselective HBP, irrespective of LBB recruitment. Successful LBBB correction was defined as selective or nonselective HBP resulting in paced QRS morphology similar to pre‐TAVR QRS and paced QRS duration (QRSd) less than 120 milliseconds with thresholds less than 3.0 V at 1.0‐millisecond pulse width. Results The study enrolled 16 patients requiring a permanent pacemaker after TAVR (age 85 ± 4 years, 31% female, all LBBB; QRSd: 161 ± 14 milliseconds). Capture of the His bundle was achieved in 13 of 16 (81%) patients. HBP with LBBB correction was achieved in 11 of 16 (69%) and QRSd narrowed from 162 ± 14 to 99 ± 13 milliseconds and 134 ± 7 milliseconds during S‐HBP and NS‐HBP, respectively (P = .005). At implantation, mean threshold for LBBB correction was 1.9 ± 1.1 V at 1.0 millisecond. Thresholds remained stable at 11 ± 4 months follow‐up (1.8 ± 0.9 V at 1.0 millisecond, P = .231 for comparison with implant thresholds). During HBP implant, one temporary complete atrioventricular block occurred. Conclusion Permanent HBP is feasible in the majority of patients with TAVR requiring a permanent pacemaker with the potential to correct a TAVR‐induced LBBB with acceptable pacing thresholds.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.